Leonton GINJ-0201-EBT-T Hardware User Manual Download Page 9

 

 

LED Indicators 

There are LED light indicators located on the front panel of the industrial injector that display the power 
status and network status. Each LED indicator has a different color and has its own specific meaning, see 
below in Table 2.1. 
  

LED

 

Color

 

Description

 

PWR

 

Green

 

On

 

Power input 1 and 2 are active

 

Red

 

On

 

Power input 1 or 2 is inactive, trigger relay

 

-

 

Off

 

Power input 1 and 2 is inactive

 

PoE

 

Amber

 

On

 

The  PoE  output  port  is  supplying  power  to  the  powered-device 
over 

2 pairs

 

Green

 

On

 

The  PoE  output  port  is  supplying  power  to  the  powered-device 
over

 4 pairs

 

Amber

 

Flashing

 

The PoE output port is supplying power to the powered-device 

 

over 

pairs after the Dual PD Check event happens.

 

(This event indictor only occurs when Dual PD Check function is disabled)

 

Green

 

Flashing

 

The PoE output port once supplied power to the powered-device 
over 2 pairs and now recovers to supply power over 4pairs.

 

-

 

Off

 

No powered-device attached or power supplying fails

 

P/L

 

-

 

Off

 

Actual Consumption 

≦ 

30W

 

Blue

 

On

 

31W 

 Actual Consumption 

≦ 

60W

 

Red

 

On

 

61W 

 Actual Consumption 

≦ 

90W

 

Red

 

Flashing

 

91W 

 Actual Consumption 

≦ 

100W

 

(This event indictor only occurs when Enhanced mode is enabled)

 

 

Table 2.1: LED Indicators 

 

 

Summary of Contents for GINJ-0201-EBT-T

Page 1: ...GINJ 0201 EBT T...

Page 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Page 3: ...tions FCC Ces limites sont con ues pour fournir une protection raisonnable contre toutes interf rences nuisibles dans un milieu r sidentiel Cet quipement g n re utilise et peut mettre de l nergie de f...

Page 4: ...t Panel 4 Top View 4 LED Indicators 5 DIP Switch Setting 6 Relay Contact Alarm Warning 6 Ethernet Ports 7 Cabling 8 Wiring the Power Inputs 8 Wiring the Fault Alarm Contact 9 Grounding Note 9 MOUNTING...

Page 5: ...ies also works perfectly in polarized temperatures from 40 75 and undoubtedly becomes your best option in a harsh environment GINJ 0201 EBT Series with a fan less design besides extending surely apply...

Page 6: ...if de protection sur l entr e d alimentation Fourniture par courant industriel homologu UL Les sp cifications mat rielles les ports les informations de c blage et l installation du c blage du converti...

Page 7: ...HARDWARE DESCRIPTION Physical Dimensions Figure 2 1 below shows the physical dimensions of GINJ 0201 EBT Series W x H x D is 30mm x 95mm x 75mm Figure 2 1 Physical Dimensions...

Page 8: ...ow shows the top panel of the GINJ 0201 EBT Series Industrial Gigabit BT PoE Injector that is equipped with one 2 pin terminal block for relay contact alarm and 4 pin terminal block connectors for dua...

Page 9: ...n The PoE output port is supplying power to the powered device over 4 pairs Amber Flashing The PoE output port is supplying power to the powered device over 2 pairs after the Dual PD Check event happe...

Page 10: ...t if an invalid detection signature is discovered on either channel the port will not perform classification or grant power on requests Note 1 When Dual PD Check is disabled in Standard PoE Mode and o...

Page 11: ...r crossover cabling See the figures as below for straight through and crossover cabling schematics 10 100BASE T X RJ 45 Pin Assignments Table 2 3 Crossover Cable Straight Through Cable Pin Number Sign...

Page 12: ...tive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 4 Figure 2 4 Power Terminal Block Step 2 Tighten the wire clamp screws to...

Page 13: ...ct is shown below in Figure 2 6 Figure 2 6 fault alarm contact Grounding Note Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the ground connecti...

Page 14: ...ting The DIN Rail is pre installed on the injector from the factory If the DIN Rail is not on the unit please see Figure 3 1 to learn how to install the DIN Rail on it Figure 3 1 The Rear Side of the...

Page 15: ...IN Rail bracket is installed on the rear side of the injector insert the top of the DIN Rail on to the track as shown below in Figure 3 2 Figure 3 2 Insert the Injector on the DIN Rail Step 4 Lightly...

Page 16: ...al Ethernet injector Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet injector Step 4 Use the hook holes at the corners of the wall mounting bracket to hang the indu...

Page 17: ...ial injector on a DIN Rail or wall please refer to the Mounting Installation section Step 4 Power on the industrial injector and then the power LED light will turn on If you need help on how to wire p...

Page 18: ...t me int grant l quipement est de la responsabilit de l assembleur du syst me Caution This is an OPEN TYPE module and should be installed in a final safety enclosure characteristic Attention Il s agit...

Page 19: ...turn on when the power cord is plugged in the user may have a problem with the power cord Check for loose power connections power losses or surges at the power outlet Please contact Leonton for techni...

Reviews: