![Leonton GINJ-0201-EBT-T Hardware User Manual Download Page 9](http://html1.mh-extra.com/html/leonton/ginj-0201-ebt-t/ginj-0201-ebt-t_hardware-user-manual_1882828009.webp)
LED Indicators
There are LED light indicators located on the front panel of the industrial injector that display the power
status and network status. Each LED indicator has a different color and has its own specific meaning, see
below in Table 2.1.
LED
Color
Description
PWR
Green
On
Power input 1 and 2 are active
Red
On
Power input 1 or 2 is inactive, trigger relay
-
Off
Power input 1 and 2 is inactive
PoE
Amber
On
The PoE output port is supplying power to the powered-device
over
2 pairs
Green
On
The PoE output port is supplying power to the powered-device
over
4 pairs
Amber
Flashing
The PoE output port is supplying power to the powered-device
over
2
pairs after the Dual PD Check event happens.
(This event indictor only occurs when Dual PD Check function is disabled)
Green
Flashing
The PoE output port once supplied power to the powered-device
over 2 pairs and now recovers to supply power over 4pairs.
-
Off
No powered-device attached or power supplying fails
P/L
-
Off
Actual Consumption
≦
30W
Blue
On
31W
≦
Actual Consumption
≦
60W
Red
On
61W
≦
Actual Consumption
≦
90W
Red
Flashing
91W
≦
Actual Consumption
≦
100W
(This event indictor only occurs when Enhanced mode is enabled)
Table 2.1: LED Indicators
Summary of Contents for GINJ-0201-EBT-T