background image

 
 
 

Leonton

 

ET2

0500

M12

67

 

Series

 

(ET2

0500

M12

67

 

/

 

ET2

0500

M12

T67)

 

 

 

 

 

 

User

 

Manual

 

Version

 

1.0

 

Summary of Contents for ET2-0500-M12-67 Series

Page 1: ...Leonton ET2 0500 M12 67 Series ET2 0500 M12 67 ET2 0500 M12 T67 User Manual Version 1 0...

Page 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Page 3: ...imites de la classe A pour les quipements num riques conform ment la section 15 des R glementations FCC Ces limites sont con ues pour fournir une protection raisonnable contre toutes interf rences nui...

Page 4: ...equired to take adequate measures CE Mark AVERTISSEMENT Ceci est un produit de classe A Dans un environnement domestique ce produit peut tre utilis en pr sence d interf rences radio This document is t...

Page 5: ...ution 1 Hardware Description 2 Physical Dimensions 2 Front Panel 3 LED Indicators 4 Grounding 4 Ethernet Ports 4 Wiring the Power Inputs 6 Mounting Installation 7 Wall Mounting 7 DIN Rail Mounting 8 H...

Page 6: ...ng an operating temperature of 10 C 65 C and another with a wide operating temperature of 40 C 75 C this series is designed to meet any needs for industrial automation application and harsh environmen...

Page 7: ...nie par un circuit externe veuillez utiliser un dispositif de protection sur l entr e d alimentation Fourniture par courant industriel homologu UL Les sp cifications mat rielles du commutateur Etherne...

Page 8: ...dware Description Physical Dimensions Figure 2 1 below shows the physical dimensions of ET2 0500 M12 67 series W x H x D is 37 13mm x 215 73mm x 32 8mm Figure 2 1 ET2 0500 M12 67 Series Physical Dimen...

Page 9: ...3 Front Panel The front panel of the ET2 0500 M12 67 series industrial unmanaged Ethernet switch is shown below in Figure 2 2 Figure 2 2 The Front Panel of ET2 0500 M12 67 Series...

Page 10: ...on for Power ACT is for Activity and L A is for Link Activity Grounding Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the ground connection fro...

Page 11: ...Female Connector Illustration Pinouts 10 100Base T X Signal 1 Transmit Data TX 2 Receive Data RX 3 Transmit Data TX 4 Receive Data RX Table 2 2 Pin assignment of M12 Ethernet connector NOTE and signs...

Page 12: ...een 18 24AWG Please follow the below steps to insert the power wire Step 1 Insert the positive and negative power wires into the power connector on the industrial Ethernet switch with pin4 pin1 V1 V1...

Page 13: ...e top and bottom side of the switch to make 2 screw holes on a wall accordingly Step 3 Insert the screws through the screw holes on the switch and screw the switch into the wall Step 4 To remove the s...

Page 14: ...l Ethernet switch and how to hang the switch Step 1 Use the screws to install the DIN Rail bracket on the rear side of the industrial Ethernet switch as shown in Figure 3 1 Figure 3 1 The Rear Side of...

Page 15: ...switch 1 Insert the top of the DIN Rail on to the track 2 Lightly pull down the bracket on to the rail 3 Check if the bracket is mounted tightly on the rail Figure 3 2 Install the Ethernet switch on...

Page 16: ...nuant lin airement jusqu une humidit relative de 50 40 C 2 L appareil est destin tre install dans un bo tier et un panneau de commande industriels 3 Pour une utilisation dans un environnement contr l...

Page 17: ...11 Please refer to the LED Indicators section for LED light indication Step 6 When all connections are set and the LED lights all show normal the installation is complete...

Page 18: ...help to identity if any problems exist Please refer to the LED Indicators section for LED light indication 4 If the power indicator LED does not turn on when the power cord is plugged in the user may...

Reviews: