14 

 

Trouble  Shooting 

 

 

Verify you  have the  right  power  cord  or  adapter.  Never  use  a  power  supply  or  adapter with  a 

non-compliant DC output voltage or it will burn the equipment. 

 

 

Select  the  proper  UTP  or  STP  cable  in  order  to  construct  the  network.  Use  an  unshielded 

twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45 co

nnections: 100Ω Category 5e for 

10M/100/1000Mbps.  Also  be  sure  that  the  length  of  any  twisted-pair  connection  does  not 

exceed 100 meters (328 feet). 

 

 

Diagnosing LED Indicators: To assist in identifying problems, the Switch can be easily monitored 

with the LED indicators which help to identity if any problems exist. 

 

Please refer to the LED Indicators section for LED light indication. 

 

 

If the power indicator LED does not turn on when the power cord is plugged in, the user may 

have a problem with the power cord. Check for loose power connections, power losses or surges 

at the power outlet. 

 

Please  contact  Leonton  for  technical  support  service,  if  the  problem  still  cannot  be 

resolved. 

 

 

If the industrial Switch LED indicators are normal and the connected cables are correct but the 

packets still cannot transmit, please check the system’s Ethernet devices’ c

onfiguration or status. 

 

For any repair or maintenance needs, please contact us. 

LEONTON TECHNOLOGIES, CO., LTD 

9F-1, No.43, Fuxing Rd., Xindian Dist.,   

New Taipei City, 231,   

Taiwan 

TEL: +886 2 22183113 

FAX: +886 2 22187391 

Summary of Contents for EG5-0800 Series

Page 1: ...LEONTON EG5 0800 Series EG5 0800 EG5 0800 T User Manual...

Page 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Page 3: ...he grantee of this device could void the user s authority to operate the equipment D claration FCC Cet quipement a t test et reconnu conforme aux limites de la classe A pour les quipements num riques...

Page 4: ...equired to take adequate measures CE Mark Avertissement Ceci est un produit de classe A Dans un environnement domestique ce produit peut tre utilis en pr sence d interf rences radio This document is t...

Page 5: ...Physical Dimensions 3 Front Panel 4 Top View 4 LED Indicators 5 Ethernet Ports 6 Cabling 7 Wiring the Power Inputs 7 Wiring the Fault Alarm Contact 8 Grounding Note 8 Mounting Installation 9 DIN Rail...

Page 6: ...erature of 10 to 65 C and another with a wide operating temperature of 40 to 75 C this series is designed to meet any needs for industrial automation outdoor application and harsh environments Key Fea...

Page 7: ...un dispositif de protection sur l entr e d alimentation Fourniture par courant industriel homologu UL Les sp cifications mat rielles les ports les informations de c blage et l installation du c blage...

Page 8: ...3 Hardware Description Physical Dimensions Figure 2 1 below shows the physical dimensions of EG5 0800 series W x H x D is 54mm x 142mm x 99mm Figure 2 1 Physical Dimensions...

Page 9: ...Front Panel Top View Figure 2 3 below shows the top panel of the EG5 0800 series switch that is equipped with one 6 pin removal terminal block connector for dual DC power inputs 12 48VDC Figure 2 3 T...

Page 10: ...s inactive FAULT Green On No event happened Red On 1 Power input 1 or 2 is inactive 2 Port link down Broken MASTER Green On ERPS Owner Mode Ring Master is ready Off ERPS Owner Mode is not active RING...

Page 11: ...raight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX 1 RX 3 TX 3 RX 6 TX 2 RX 6 TX 6 RX Table 2 2 1000BASE T RJ 45...

Page 12: ...rt the positive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 4 Figure 2 4 Power Terminal Block Step 2 Tighten the wire clam...

Page 13: ...1 to Pin 5 and Pin 2 to Pin 6 to eliminate power fault alarm Attention Le calibre des fils du bornier doit tre compris entre 12 et 24 AWG Si vous n utilisez qu une seule source d alimentation jumelez...

Page 14: ...ure 3 1 The Rear Side of the Switch and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Ethernet switch Step 1 Use the screws to install the DIN Rail bracket on the rear si...

Page 15: ...ull down the bracket on to the rail as shown below in Figure 3 3 Figure 3 3 Stable the Switch on DIN Rail Step 5 Check if the bracket is mounted tightly on the rail Step 6 To remove the industrial Eth...

Page 16: ...strial Ethernet switch Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Step 4 Use the hook holes at the corners of the wall mounting bracket to hang the indu...

Page 17: ...ring the Power Inputs section Please refer to the LED Indicators section for LED light indication Step 5 Prepare the twisted pair straight through category 5 cable for Ethernet connection Step 6 Inser...

Page 18: ...st me int grant l quipement est de la responsabilit de l assembleur du syst me Caution This is an OPEN TYPE module and should be installed in a final safety enclosure characteristic Attention Il s agi...

Page 19: ...which help to identity if any problems exist Please refer to the LED Indicators section for LED light indication If the power indicator LED does not turn on when the power cord is plugged in the user...

Reviews: