Troubleshooting and fault elimination
Fault messages
EN
46
Lenze ¯ MDKSEMA ¯ 5.0
6.2
Fault messages
Fault
Possible cause
Remedy
Type Message
F
RFID read error (RFIR)
NFC communication interrupted
1. Connect and disconnect mains.
2. Repeat action.
3. If the error occurs again, please contact
the Lenze Service.
F
RFID write error (RFIW)
F
RFID data CRC invalid (PS02)
NFC communication interrupted
1. Load default setting.
2. Connect and disconnect mains.
3. Rewrite parameter set.
F
RFID data version invalid (PS04)
Incompatible software version
Update Lenze App or EASY Starter.
F
Missing mains phase (SU02)
A mains phase of a three−phase supply has
failed. Reliable detection from an
utilisation > 50 % rated motor power.
¯
Check mains connection.
¯
Check fuses.
F
DC bus overvoltage (OU)
DC−bus voltage too high
¯
Increase deceleration ramp.
¯
Reduce speed for great regenerative
loads.
¯
Use brake resistor.
W
Electronics warning temperature (OH4)
Lacking or insufficient cooling.
Drive close to being disconnected due to
overtemperature (OH1)
¯
Check cooling.
¯
Clean cooling ribs.
F
Electronics overtemperature (OH1)
Ambient temperature too high.
Ambient temperature must be in the
permissible range.
F
Electronics overload (Ixt ) (OC9)
The Ixt overload test has been triggered
¯
Motor load too high.
¯
Load cycles not complied with.
¯
Increase deceleration ramp.
¯
Reduce I
max
.
¯
Check dimensioning.
F
Electronics overcurrent (OC11)
Overcurrent limitation active
¯
Reduce motor load.
¯
Increase deceleration ramp.
F
Motor overcurrent (OC7)
The maximum current monitoring
function has been triggered.
Reduce motor load.
F
Motor short circuit (OC1)
Short circuit in the motor phases
Reset error. If the error occurs again during
restart, please contact the Lenze Service.
F
Motor earth fault (OC2)
A motor phase has earth contact
F
Motor overload I
2
xt (OC6)
Motor thermally overloaded
¯
Reduce motor load.
¯
Check setting of the I
2
xt monitoring
function.
¯
Increase deceleration ramp.
F
Brake resistor overload I
2
xt (OC12)
Too frequent and too long braking
processes
Check drive dimensioning.
Lenze Smart motor without brake resistor:
DC−bus voltage too high
¯
Reduce regenerative load.
¯
Use brake resistor.
¯
Increase deceleration ramp.
F
Internal error (DH69)
Various
Reset error. If the error occurs again during
restart, please contact the Lenze Service.
F
Internal error (DF01)
...
Internal error (DF13)
Various