![Lenze MOBILE Advanced DCU Hardware Manual Download Page 41](http://html1.mh-extra.com/html/lenze/mobile-advanced-dcu/mobile-advanced-dcu_hardware-manual_1882381041.webp)
Installation
Mechanical installation
Ò
41
EDSMDAG EN 2.0
5.2
Mechanical installation
EMDAG2..., EMDAG3..., EMDAG4...
The mounting material must ensure a durable mechanical connection. The fixing points
are dimensioned for:
ƒ
M10 cheese head screw, hexagon socket, according to DIN 912/ISO 4762
ƒ
M10 cheese head screw, torx, according to ISO 14579
g
3
g
3
g
3
b
g
b
1
h
c
3
d
3
c
4
t
c
5
3×
M
1
0
r
X11 / X12 / X13
3×
EMDAG002
h
b
t
b
1
c
3
c
4
c
5
d
3
g
3
r
Ý
[mm]
[kg]
EMDxG2...
310
394
81
355
331
165.5
165.5
286
Ø 11
106
7.0
EMDxG3...
8.4
EMDxG4...
8.4