![Lenze MOBILE Advanced DCU Hardware Manual Download Page 35](http://html1.mh-extra.com/html/lenze/mobile-advanced-dcu/mobile-advanced-dcu_hardware-manual_1882381035.webp)
Technical data
Control of MOBILE DCU S
Thermal sensor input
Ò
35
EDSMDAG EN 2.0
4.4.3
Thermal sensor input
Thermal sensor input
Value
Evaluable thermal sensors
PT1000, KTY83/110, KTY84/130,
PTC acc. to DIN44081,
thermostat (normally−closed contact) acc. to
DIN44080
Diagnostics option
Wire breakage/short circuit
Resistance measuring range
W
280 ... 3050
Limit frequency of input filter
Hz
10
Resolution
Bit
12
4.4.4
CAN bus
Public CAN and Private CAN communicate via a bus cable.
Public CAN, Private CAN
Protocol
Public CAN
SAE J1939
Private CAN
CANopen
Baud rate
kbps
125, 250, 500
Max. cable length
at 125kbps
m
250
at 250kbps
m
250
at 500kbps
m
100
Loop delay of all nodes
ns
<200