Technical data
General data and operating conditions
4
19
Lenze ¯ BA 33.0008 ¯ 5.0
4
Technical data
4.1
General data and operating conditions
General data
Conformity and approval
Conformity
CE
2014/35/EU
Low−Voltage Directive
2009/125/EC
ErP Directive
Regulation No. 4/2014 and No. 640/2009 on the
ecodesign of electric motors
2014/30/EU
EMC Directive
EAC
TP TC 004/2011
(TR CU 004/2011)
On safety of low voltage
equipment
Eurasian Conformity
TR CU: Technical Regulation of
Customs Union
EAC
TP TC 020/2011
(TR CU 020/2011)
Electromagnetic
compatibility of technical
means
Eurasian Conformity
TR CU: Technical Regulation of
Customs Union
Approvals
UL
UL 1004−8
File No. E210321
Inverter Duty Motors
Motors and Generators
CSA
CSA C22.2 No. 100
Energy Verified
CFR Part 431.23
File No. E210321
CC1278B
Energy Efficiency Program for
Certain Commercial and
Industrial Equipment
CSA C390−10
Energy Efficiency Test
Methods for Three−Phase
Induction Motors
CCC
GB Standard
12350−2009
Safety requirements of small−power motors
The applicable approvals for the product you have ordered require labelling and are
specified on the nameplate.
Protection of persons and devices
Enclosure
IEC/EN 60034−5
See nameplate
Degrees of protection only apply to horizontal installation
All unused connectors must be closed with protection
covers or blanking plugs.
Temperature class
F (155 °C)
IEC/EN 60034−1
Exceedance of the temperature limit weakens or destroys
the insulation
Operating conditions
Ambient conditions
Climatic
Transport
IEC/EN 60721−3−2
2K3 (−20 °C ... +70 °C)
Storage
IEC/EN 60721−3−1
1K3 (−20 °C ... +60 °C)
< 3 months
1K3 (−20 °C ... +40 °C)
> 3 months
Operation
IEC/EN 60721−3−3
3K3 (−20 °C ... +40 °C)
Without brake
3K3 (−10 °C ... +40 °C)
With brake
> +40 °C
With power reduction, see
catalogue
Site altitude
< 1000 m amsl − without power reduction
> 1000 m amsl < 4000m amsl with power reduction, see
catalogue
Humidity
Relative humidity
£
85 %, without condensation
Mechanical
IEC/EN60721−3−3
3M6