4
Technical data
General data
EDK94AYCER DE/EN/FR/ES/IT 6.1
36
H1_Daten−GHB Servo Drives 9400
4
Technical data
General data
Field
Values
Order designation
E94AYCER
Communication medium
CAT 5e
Network topology
Tree, star and line
Number of stations
Max. 255 in the subnetwork
Max. cable length
100 m
PROFINET stations
IO device with real time communication features (RT)
PNO identification no.
0x0106
hex
Device identification
(device ID)
0x9400
hex
Baud rate
100 Mbps
Switching method
"Store−and−forward"
Switch latency
Approx. 125
s for maximum telegram length
Voltage supply
External supply via separate power supply unit
l
"+": U = 24 V DC (20.4 V...28.8 V), I = 130 mA
l
"−": reference potential for external voltage supply
Conformities, approvals
l
CE
l
EAC
l
UL
"Servo Drives 9400" hardware manual
Here you can find the
ambient conditions
and the
electromagnetic
compatibility (EMC)
specifications applying to the communication module.
Summary of Contents for L-force PROFINET E94AYCER
Page 2: ... DUMMYSEITEVOR ...
Page 4: ...EDK94AYCER DE EN FR ES IT 6 1 4 klappseite E94ZAYCER DUMMY_NUM_Reset E94YCER001B E94AYCET017 ...
Page 26: ...EDK94AYCER DE EN FR ES IT 6 1 26 klappseite E94ZAYCER DUMMY_NUM_Reset E94YCER001B E94AYCET017 ...
Page 48: ...EDK94AYCER DE EN FR ES IT 6 1 48 klappseite E94ZAYCER DUMMY_NUM_Reset E94YCER001B E94AYCET017 ...
Page 70: ...EDK94AYCER DE EN FR ES IT 6 1 70 klappseite E94ZAYCER DUMMY_NUM_Reset E94YCER001B E94AYCET017 ...
Page 92: ...EDK94AYCER DE EN FR ES IT 6 1 92 klappseite E94ZAYCER DUMMY_NUM_Reset E94YCER001B E94AYCET017 ...