15
Parameter reference
15.2
Parameter list
914
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00508
Bit 1 Parameter write protection
1
≡
The currently used communication channel cannot
be used to write into write/read parameters.
Bit 2 Parameter read protection
1
≡
The currently used communication channel cannot
be used to read write/read parameters.
Bit 3
Reserved
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15 Memory module binding on
1
≡
Device personalisation is active. All write/read
actions between inverter and memory module are only
executed if both components have the same binding ID.
Subcodes
Info
C00507/1
Password protection - all communication channels
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Parameter | Name:
C00507 | Current password protection
Data type: UNSIGNED_16
Index: 24068
d
= 5E04
h
Parameter | Name:
C00508 | PW protection config X6(DIAG)
Data type: UNSIGNED_16
Index: 24067
d
= 5E03
h
From version 15.00.00
Configuration of the password protection for parameter access via diagnostic interface X6 ("DIAG")
Individual password protection for single communication channels
Setting range
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0
Reserved
Bit 1 Parameter write protection
The diagnostics interface X6 cannot be used to write into
write/read parameters.
Bit 2 Parameter read protection
The diagnostics interface X6 cannot be used to read
write/read parameters.
Bit 3
Reserved
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Reserved