15
Parameter reference
15.2
Parameter list
862
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00221
C00222
C00223
C00224
C00225
Parameter | Name:
C00221 | L_NSet_1: Deceleration time - add. setpoint
Data type: UNSIGNED_32
Index: 24354
d
= 5F22
h
The
FB: Deceleration time for the additional setpoint
nNAdd_a
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
s
999.999
0.000 s
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1000
Parameter | Name:
C00222 | L_PCTRL_1: Vp
Data type: INTEGER_16
Index: 24353
d
= 5F21
h
The
FB: Gain factor Vp for the PID process controller
Setting range
(min. value | unit | max. value)
Lenze setting
0.1
500.0
1.0
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 10
Parameter | Name:
C00223 | L_PCTRL_1: Tn
Data type: UNSIGNED_16
Index: 24352
d
= 5F20
h
The
FB: Reset time Tn for the PID process controller
Setting range
(min. value | unit | max. value)
Lenze setting
20
ms
6000
400 ms
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00224 | L_PCTRL_1: Kd
Data type: UNSIGNED_16
Index: 24351
d
= 5F1F
h
The
FB: Derivative-action coefficient Kd for the PID process controller
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
5.0
0.0
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 10
Parameter | Name:
C00225 | L_PCTRL_1: MaxLimit
Data type: INTEGER_16
Index: 24350
d
= 5F1E
h
The
FB: Maximum output value of the PID process controller
Setting range
(min. value | unit | max. value)
Lenze setting
-199.99
%
199.99
199.99 %
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100