
15
Parameter reference
15.2
Parameter list
858
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00189
C00190
C00191
Parameter | Name:
C00189 | Resp. to too frequent AutoFailReset
Data type: UNSIGNED_8
Index: 24386
d
= 5F42
h
Response to exceeding the maximum number of "AutoFailReset" processes set in
.
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00190 | L_NSet_1: Setpoint arithmetic
Data type: UNSIGNED_8
Index: 24385
d
= 5F41
h
The
FB: Selection of arithmetics
• To be able to influence the main setpoint (NSet) by an additional setpoint (NAdd).
Selection list
(Lenze setting printed in bold)
0 Out = Set
1 Out = Set + Add
2 NOut = NSet - NAdd
3 NOut = (NSet * NAdd) / 100%
4 NOut = (NSet * 1%) / |NAdd|
5 Out = (Set*100%)/(100%-Add)
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00191 | Logbook access index User
Data type: UNSIGNED_8
Index: 24384
d
= 5F40
h
From version 12.00.00
Setting range
(min. value | unit | max. value)
0
255
Subcodes
Lenze setting
Info
C00191/1
255
Logbook access index User
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1