Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
69
3
Commissioning
3.8
Commissioning of the "Table positioning" technology application
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.8.2
Creating an »Engineer« project & going online
The following steps serve to describe a general method for creating a project with the
Select
component from catalogue
option. For this purpose, individual components ( inverter, motor, etc.)
are selected from selection lists.
1. Start »Engineer«.
2. Create a new project with the
Start-up wizard
and the
Select component from catalogue
option:
• In the
Component
step, select the 8400 HighLine inverter.
• In the
Device modules
step, select the available communication module.
• In the
Application
step, select the "Table positioning" application. (The application can also
be selected any time afterwards via the
Application parameter
tab or
• Select the other components (motor/gearbox) to be added to the project in the
Other
components
dialog step.
3.
Going online.
After a connection to the inverter has been established, the following status is displayed in the
Status line
:
4.
Download parameter set.
This command serves to overwrite the current parameter settings in the inverter by parameter
settings of the »Engineer« project.
You can find detailed information on the general use of the »Engineer« in the online help
which you can call with
[F1]
.
• In the "Working with projects" chapter, all options of the
start-up wizard
are described
to create a new »Engineer« project.