17
Function library
17.1
Function blocks | L_OffsetGainP_2
1451
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.124
L_OffsetGainP_2
This FB can add an offset to an analog input signal and amplify it afterwards. Preferably to be
interconnected directly after the analog input terminals.
• The internal calculations (addition and subtraction) are carried out with 32 bits without
overflow/underflow. Division is not remainder considered.
• Offset and gain are selected via parameters.
• The value provided at the
nOut_a
output is internally limited to ±199.99 %.
Inputs
Outputs
Parameters
Function
Designator
Data type
Information/possible settings
nIn_a
INT
Input signal
Designator
Data type
Value/meaning
nOut_a
INT
Output signal
• Internal limitation to ±199.99 %
Parameters
Possible settings
Info
-100.0000
100.0000 Gain factor
• High gain factor for further
processing of smallest input
signals.
• Please observe the difference
with regard to the gain factors of
other blocks in percent
(±199.99 %
≈
2).
• Lenze setting: 1.0000
-199.99
%
199.99 Offset
• Lenze setting: 0.00 %
/B2IIVHW*DLQ3B
Q2XWBD
Q,QBD
2IIVHW
*DLQ
&
&
nOut_a
nIn_a Offset
+
(
)
Gain factor
⋅
=