
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
1346
17
Function library
17.1
Function blocks | L_DFRFG_1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Outputs
Parameters
Designator
Data type
Value/meaning
bSync
BOOL
Status signal "Drive is running synchronously"
TRUE The drive is running synchronously, the speed input id directly
applied to the speed output.
nOut_v
INT
Speed/angle setpoint
• Scaling: 16384
≡
15000 rpm
bFail
BOOL
Status signal "Angular difference exceeded"
TRUE The angular difference set in
has been exceeded.
Parameters
Possible settings
Info
0.000
s
999.900 Acceleration and deceleration time
• Relating to the reference speed
(constant acceleration and
deceleration) set in
• It is a maximum value which
limits the acceleration of the
ramp function generator.
• Lenze setting: 1.000 s
0.000
s
999.900 Deceleration time for quick stop of
the slave drive
• Relating to the reference speed
(constant acceleration and
deceleration) set in
• It is a maximum value which
limits the deceleration of the
ramp function generator.
• Lenze setting: 0.000 s
1
rpm
15000 Max. speed-up
• Lenze setting: 3000 rpm
10
Incr.
2000000000 Following error limit
• Scaling: A revolution is displayed
with 65536 increments or steps.
• Lenze setting: 2000000000 incr.
0
Incr.
65535 Synchronisation window (position)
• If the difference between the
master and the slave is lower than
the synchronisation window, the
bSync
status signal is set to TRUE.
• Lenze setting: 100 incr.
-2147483647
Incr.
2147483647 Offset
• Angular offset for the internal
actual position of the FB
• Scaling: A revolution is displayed
with 65536 increments or steps.
• Lenze setting: 0 incr.