15
Parameter reference
15.2
Parameter list
1044
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01049
C01050
C01051
C01052
Parameter | Name:
C01049 | L_CalcDiameter_1: Status
Data type: INTEGER_16
Index: 23526
d
= 5BE6
h
From version 11.00.00
Display range
(min. value | unit | max. value)
-10
30
Subcodes
Info
C01049/1
: Status
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01050 | L_CalcDiameter_1: Diameter recalculation
Data type: UNSIGNED_32
Index: 23525
d
= 5BE5
h
From version 11.00.00
Setting range
(min. value | unit | max. value)
0.001
Rev.
1000.000
Subcodes
Lenze setting
Info
C01050/1
1.000 rev.
: Diameter recalculation 0
C01050/2
0.100 rev.
: Diameter recalculation 1
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1000
Parameter | Name:
C01051 | L_CalcDiameter_1: Filter time constant
Data type: UNSIGNED_16
Index: 23524
d
= 5BE4
h
From version 11.00.00
Setting range
(min. value | unit | max. value)
0.010
s
3.000
Subcodes
Lenze setting
Info
C01051/1
1.000 s
: Filter time constant
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1000
Parameter | Name:
C01052 | L_CalcDiameter_1: Web break monitoring
Data type: INTEGER_16
Index: 23523
d
= 5BE3
h
From version 11.00.00
Setting range
(min. value | unit | max. value)
0.00
%
100.00
Subcodes
Lenze setting
Info
C01052/1
10.00 %
: Permissible diameter change
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100