11.2.3
Control commands and status information
The following control commands can be executed in the "cyclically synchronous torque" oper-
ating mode via the CiA402 control word
Control word
State Function
Bit 4
0
reserved (bit must be set to "0")
Bit 5
0
reserved (bit must be set to "0")
Bit 6
0
reserved (bit must be set to "0")
Bit 8
0↗1
Stop
The following status information are output via the CiA402 status word
in the "cyclic
sync torque mode":
Status word
State Meaning
Bit 12
0
"Cyclic sync torque mode" is inactive
1
"Cyclic sync torque mode" is active
Configuring the torque control
Operating mode "CiA 402 Cyclic sync torque mode (cst)"
Control commands and status information