Technical data
Standards and operating conditions
Conformities/approvals
Conformity
CE
2014/35/EU
Low-Voltage Directive
2014/30/EU
EMC Directive (reference: CE-typical drive system)
EAC
TR TC 004/2011
Eurasian conformity: safety of low voltage equipment
TP TC 020/2011
Eurasian conformity: electromagnetic compatibility of technical
means
Approval
CCC
GB Standard 12350-2009
cULus
UL 61800-5-1
for USA and Canada (requirements of the CSA 22.2 No. 14)
Industrial Control Equipment, Lenze File No. E132659
Protection of persons and device protection
Degree of protection
IP55
EN 60529
Type 4 indoor only
Type 12
NEMA 250
Insulation resistance
Overvoltage category III
EN 61800-5-1
Site altitude 0 … 2000 m above sea level
Overvoltage category II
EN 61800-5-1
Site altitude more than 2000 m above sea level:
External measures for compliance with overvoltage category II are
necessary, e.g. connection of an isolating transformer upstream ,
connection of an overvoltage protection device upstream
Protective insulation of control circuits
Safe separation from the mains supply by means
of double/increased insulation for digital inputs
and outputs
EN 61800-5-1
Site altitude 0 … 2000 m above sea level
Upstream connection of overvoltage protection
device
EN 61800-5-1
Site altitude more than 2000 m above sea level:
Additional external separating measures necessary for purposes of
safe separation.
Protective measures against
Short circuit
EN 61800−5−1
To a limited extent, fault acknowledgement necessary
earth fault
EN 61800−5−1
To a limited extent, fault acknowledgement necessary
Overvoltage
Yes
Motor stalling
Yes
Motor overtemperature
I
2
xt-monitoring
Leakage current
> 3.5 mA AC, > 10 mA DC
EN 61800-5-1
Observe regulations and safety instructions!
Equipotential bonding
Additional M5 thread with terminal at the terminal box for con-
nection of a 6 mm
2
PE cable
Total fault current
Residual current operated switch 30 mA, Type B
In TN power supply systems
Cyclic mains switching
3 times a minute, max. 20 times per hour
Mains switching 3 times in one minute must be followed by a
pause of 9 minutes.
Starting current
5.6 A mains power-on current
Technical data
Standards and operating conditions
Conformities/approvals
24