Mechanical installation
Important notes
5
l
34
EDKZS3YA200 DE/EN/FR/ES/IT 3.0
5
Mechanical installation
5.1
Important notes
ƒ
The mounting location must always comply with the operating conditions
specified in the technical data (
¶
31). Take additional measures if
necessary.
ƒ
The mounting plate of the control cabinet must have the following
properties:
–
electrically conductive
–
free of lacquer
ƒ
The mechanical connections must always be ensured.
ƒ
A free air circulation must be ensured for dissipating the heat.
(
Stop!
Heavy device weight
The device is very heavy and must be lifted for the mounting.
Possible consequences:
ƒ
Injury to persons, particularly backache when lifting and holding
the device, respectively
ƒ
Injury to persons and damage to material assets due to the
device falling down
Protective measures:
ƒ
The device must only be carried with a load bearing system such
as an indoor crane permitted for the device weight
ƒ
Before the transport, the hoist, the load bearing system and
lifting accessories must be checked for sufficient payload and
faultless status
ƒ
Do not remove the hoist and the lifting accessories until the
device lies safe on a stable surface or is finally mounted.
5.2
Mounting steps
How to install the filter:
1. Screw down the fixing brackets of the filter at the mounting place.
The mounting place and material must ensure a durable mechanical
connection.