background image

U

V

PE

W

U

V

W

KTY

U

V

W

KTY

Montageanleitung

Mounting Instructions

Instructions de montage

Instrucciones para el montaje

Istruzioni per il montaggio

EDKYFYXA00−A00

.Y&a

Ä.Y&aä

EYF 

l

EYFxxxxYxxxxA00A00

Systemleitung für Rückführungsanschluss

System cable for feedback connection

Câble système pour raccordement bouclage

Cable de sistema para conexión de la realimentación

Cavo di sistema per collegamento di retroazione

L−force

  Communication

Summary of Contents for EYF Series

Page 1: ...je Istruzioni per il montaggio EDKYFYXA00 A00 Y a Ä Y aä EYF l EYFxxxxYxxxxA00A00 Systemleitung für Rückführungsanschluss System cable for feedback connection Câble système pour raccordement bouclage Cable de sistema para conexión de la realimentación Cavo di sistema per collegamento di retroazione L force Communication ...

Page 2: ... well as the manual System Cables and System Connectors Lire la documentation relative à l appareil de base et au moteur ainsi que le manuel Câbles système et connecteurs système avant toute manipulation de l équipement Antes de empezar con el trabajo lea detenidamente la documentación del equipo básico y del motor así como el manual Cables y conectores de sistema Prima di utilizzare l apparecchia...

Page 3: ... Y xxxx A00 A00 xxxx 0 1 m 0017 3 2 0 14 mm2 3 0 14 mm2 3 2 AWG 26 3 AWG 26 9 4 mm d 0020 3 2 0 14 mm2 3 0 14 mm2 3 2 AWG 26 3 AWG 26 9 3 mm U V W KTY U V PE W EYF xxxx Y xxxx A00 A00 BK BK BK PK GY GN BK YE RD REF REF COS COS SIN SIN KTY KTY Vcc Vcc KTY KTY REF REF COS COS SIN SIN yfyaa_2 ...

Page 4: ... 4 2 0 14 mm2 2 1 0 mm2 4 2 AWG 26 2 AWG 18 11 4 mm d 0019 4 2 0 14 mm2 2 1 1 0 mm2 4 2 AWG 26 2 1 AWG 18 10 8 mm d U V W KTY U V PE W BK BK BK BU GN BK YE RD WH BN EYF xxxx Y xxxx A00 A00 B B SIN SIN RefSIN RefSIN COS COS RefCOS RefCOS A A Z Z RS485 RS485 KTY KTY KTY KTY Vcc Vcc GND GND B B A A Z Z RS485 RS485 yfyaa_3 ...

Page 5: ...2 AWG 26 4 AWG 26 2 2 AWG 20 12 0 mm d 0024 5 2 0 14 mm2 4 0 14 mm2 2 0 5 mm2 5 2 AWG 26 4 AWG 26 2 AWG 20 12 6 mm BK BK BK YE BK RD BK EYF0024 BK OG EYF0024 BU YE RD BK BK GN BN WH VT U V W KTY U V PE W EYF xxxx Y xxxx A00 A00 Sense Sense Sense Sense Clock Clock Clock Clock B B A A Z Z Data Data Data Data KTY KTY KTY KTY Vcc Vcc GND GND B B A A Z Z yfyaa_5 ...

Page 6: ...2 0 14 mm2 4 0 14 mm2 2 0 5 mm2 5 2 AWG 26 4 AWG 26 2 AWG 20 12 6 mm d 0024 5 2 0 14 mm2 4 0 14 mm2 2 0 5 mm2 5 2 AWG 26 4 AWG 26 2 AWG 20 U V W KTY U V PE W EYF xxxx Y xxxx A00 A00 BK BK BK YE BK RD BK BK BU YE RD BK BK OG GN BN WH VT U A V B Z W KTY KTY Vcc GND U A V B Z W U A V B Z W KTY KTY Vcc GND U A V B Z W yfyaa_6 ...

Page 7: ..._HB_DE EYF_UL_ohne_ohne_fest d r r 5 d r 7 5 d r 10 d v a n v v 3 m s a a 5 m s2 n n 2 5 Mio GN BK silicone halogen silicone halogen Q UL Recognized 2014 35 EU AVLV2 AVLV8 50 V 300 V 80 C 80 C Q UL Recognized 2014 35 EU AVLV2 AVLV8 50 V 300 V 80 C 80 C ...

Page 8: ...xtertal GERMANY HR Lemgo B 6478 Service Lenze Service GmbH Breslauer Straße 3 D 32699 Extertal Germany 49 5154 82 0 008000 2446877 24 h helpline Ê 49 5154 82 2800 Ê 49 5154 82 1112 sales de lenze com service de lenze com ü www lenze com EDKYFYXA00 A00 Y a DE EN FR ES IT 8 0 TD15 10 9 8 7 6 5 4 3 2 1 ...