Function library
Function blocks
3.2.9
Analog inputs via terminal X6/1, X6/2 and X6/3, X6/4 (AIN)
3−45
l
EDSVS9332K−EXT EN 4.0
3.2.9
Analog inputs via terminal X6/1, X6/2 and X6/3, X6/4 (AIN)
Purpose
These function blocks are the interface for analog signals as the
l
setpoint input,
l
actual value input and
l
parameter control.
C0034
1
2
AIN1
+
+
AIN1-OUT
AIN1-GAIN
AIN1-OFFSET
C0404/1
C0404/2
C0402
C0403
C0400
Fig. 3−20
Analog input via terminal X6/1, X6/2 (AIN1)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
AIN1−OFFSET
a
C0404/1
dec [%]
C0402
1
19502
−
AIN1−GAIN
a
C0404/2
dec [%]
C0403
1
19504
−
AIN1−OUT
a
C0400
−
−
−
−
−
Special features of AIN1
l
A dead band element can be integrated into the output signal at AIN1 via code C0034.
Together with the jumper position X2 (controller front) the function 4 ... 20 mA can be
implemented as a master current value.
l
The signal is read cyclically (1 ms).
3
4
AIN2
+
+
AIN2-OUT
AIN2-GAIN
AIN2-OFFSET
C0409/1
C0409/2
C0407
C0408
C0405
Fig. 3−21
Analog input via terminal X6/3, X6/4 (AIN2)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
AIN2−OFFSET
a
C0409/1
dec [%]
C0407
1
19503
−
AIN2−GAIN
a
C0409/2
dec [%]
C0408
1
19505
−
AIN2−OUT
a
C0405
−
−
−
−
−
Special feature of AIN2
l
The signal is read cyclically every 250
s.
Summary of Contents for EVS93 Series
Page 2: ......
Page 8: ...Preface and general information 1 2 l EDSVS9332K EXT EN 4 0...
Page 14: ...Preface and general information Definition of the notes used 1 8 l EDSVS9332K EXT EN 4 0...
Page 16: ...Configuration 2 2 l EDSVS9332K EXT EN 4 0...
Page 28: ...Configuration Operating modes 2 3 2 Control 2 14 l EDSVS9332K EXT EN 4 0...
Page 32: ...Function library 3 4 l EDSVS9332K EXT EN 4 0...
Page 362: ...Application examples 4 2 l EDSVS9332K EXT EN 4 0...
Page 374: ...Application examples 4 4 Mark controlled cam profile start 4 14 l EDSVS9332K EXT EN 4 0...
Page 376: ...Appendix 5 2 l EDSVS9332K EXT EN 4 0...
Page 385: ......