Function library
Function blocks
3.2.38
Characteristic function (CURVEC)
3−132
l
EDSVS9332K−EXT EN 4.0
3.2.38
Characteristic function (CURVEC)
Purpose
The function block serves to map analog profiles.
C U R V E C 1
C U R V E C 1 - A I N
0
1
2
3
4
5
6
7
C U R V E C 1 - A O U T
C 1 3 2 0 / 1
C 1 3 2 1 / 1
C 1 3 1 0
C U R V E C 1 - H O L D
C 1 3 2 2 / 9
C 1 3 2 3 / 9
C U R V E C 1 - I N
C 1 3 2 4 / 5
C 1 3 2 5 / 5
C U R V E C 1 - S E L - I N
C 1 3 2 2 / 1 0
C 1 3 2 3 / 1 0
C U R V E C 1 - O U T
C U R V E C 1 - X < 0
C U R V E C 1 - X > X M A X
C U R V E C 1 - D F O U T
0
1
C U R V E C 1 - B U S Y
C U R V E C 1 - R E L - S E L
C 1 3 2 2 / 1 1
C 1 3 2 3 / 1 1
C U R V E C 1 - X R E S E T
C 1 3 2 2 / 1 2
C 1 3 2 3 / 1 2
C U R V E C 1 - C A M - S E L - B U S Y
C U R V E C 1 - I N I T - D F O U T
fb_curvec
Fig. 3−100
Characteristic function (CURVEC)
Signal
Source
Note
Name
Type DIS/selectio
n
DIS format
CFG
List
CURVEC1−SEL−IN
d
C1323/10
C1322/10
2
HIGH = input CURVEC−IN active
CURVEC1−AIN
a
C1321/1
C1320/1
1
Analog input (analog profile)
CURVEC1−IN
ph
C1325/5
C1324/5
3
Angle input
CURVEC1−HOLD
d
C1323/9
C1322/9
1
HIGH = outputs CURVEC−OUT and CURVEC−AOUT are
stored
DFOUT = 0
CURVEC1−REL−SEL
d
C1323/11
C1322/11
1
HIGH = feed function
CURVEC1−XRESET
d
C1323/12
C1322/12
1
HIGH = sets the input values internally = 0.
See notes about CURVEC1−CAM−SEL−BUSY.
CURVEC1−X<0
d
HIGH = input value < 0
CURVEC1−X>Xmax
d
HIGH = input value > X
max
CURVEC1−BUSY
d
LOW−HIGH edge = The point distribution is not optimal,
select less points"
CURVEC1−AOUT
a
Analog output
CURVEC1−OUT
ph
Angle output
CURVEC1−DFOUT
phd
DF/speed output
CURVEC1−CAM−SEL−BUSY
d
The output remains HIGH as long as the profile
changeover (C1310) is not completed.
During this procedure, the input CURVEC1−XRESET must
be HIGH.
CURVEC1−INIT−DFOUT
d
HIGH= the drive speed does not reach the setpoint
defined by the position output. During this deviation which
may last over several cycles, a great position change is
output at the speed output. Increments do not get lost!
Therefore, the drive should only be enabled after
switching−on if CURVEC−INIT−DFOUT
LOW !
Summary of Contents for EVS93 Series
Page 2: ......
Page 8: ...Preface and general information 1 2 l EDSVS9332K EXT EN 4 0...
Page 14: ...Preface and general information Definition of the notes used 1 8 l EDSVS9332K EXT EN 4 0...
Page 16: ...Configuration 2 2 l EDSVS9332K EXT EN 4 0...
Page 28: ...Configuration Operating modes 2 3 2 Control 2 14 l EDSVS9332K EXT EN 4 0...
Page 32: ...Function library 3 4 l EDSVS9332K EXT EN 4 0...
Page 362: ...Application examples 4 2 l EDSVS9332K EXT EN 4 0...
Page 374: ...Application examples 4 4 Mark controlled cam profile start 4 14 l EDSVS9332K EXT EN 4 0...
Page 376: ...Appendix 5 2 l EDSVS9332K EXT EN 4 0...
Page 385: ......