Function library
Function blocks
3.2.34
Conversion (CONVPHPHD2)
3−124
l
EDSVS9332K−EXT EN 4.0
3.2.34
Conversion (CONVPHPHD2)
(
STOP!
This function block is not suitable for transmitting the virtual line shaft (electrical
shaft).
Purpose
The function block converts a angle change into a speed (digital frequency).
C1450/2
C1451/2
CONVPHPHD2-IN
CONVPHPHD2-OUT
CONVPHPHD2-LIM
CONVPHPHD2
CONVPHPHD2-RESET
C1454
C1455
FB_convphphd2
Fig. 3−93
Conversion (CONVPHPHD2)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
CONVPHPHD2−IN
ph
1451/2
dec [inc]
1450/2
3
1000
Angle input (reference: 65536 inc = 1 revolution)
CONVPHPHD2−RESET
d
1455
dec [inc]
14554
2
1000
As long as CONVPHPHD2−RESET = HIGH, the signal
at CONVPHPHD2−OUT is set to n = 0.
CONVPHPHD2−OUT
phd
−
−
−
−
Signal is limited to ±29999 rpm
No position loss when signal is limited
CONVPHPHD2−LIM
d
−
−
−
−
HIGH = signal at CONVPHPHD2−OUT is limited
(Function is available as of software version 3.4)
Function
An angle change at input CONVPHPHD2−IN is converted to a speed and output at
CONVPHPHD2−OUT.
Summary of Contents for EVS93 Series
Page 2: ......
Page 8: ...Preface and general information 1 2 l EDSVS9332K EXT EN 4 0...
Page 14: ...Preface and general information Definition of the notes used 1 8 l EDSVS9332K EXT EN 4 0...
Page 16: ...Configuration 2 2 l EDSVS9332K EXT EN 4 0...
Page 28: ...Configuration Operating modes 2 3 2 Control 2 14 l EDSVS9332K EXT EN 4 0...
Page 32: ...Function library 3 4 l EDSVS9332K EXT EN 4 0...
Page 362: ...Application examples 4 2 l EDSVS9332K EXT EN 4 0...
Page 374: ...Application examples 4 4 Mark controlled cam profile start 4 14 l EDSVS9332K EXT EN 4 0...
Page 376: ...Appendix 5 2 l EDSVS9332K EXT EN 4 0...
Page 385: ......