Function library
Function blocks
3.2.21
Following error monitoring (CERR)
3−82
l
EDSVS9332K−EXT EN 4.0
3.2.21
Following error monitoring (CERR)
One function block (CERR1) is available.
Purpose
Following error monitoring with pre−warning stage.
C 1 3 8 0 / 1
C 1 3 8 9 / 1
C E R R 1
C E R R 1 - E R R
C E R R 1 - P H I - I N
C 1 3 8 9 / 2
C 1 3 8 8 / 1
C 1 3 8 8 / 2
C E R R 1 - W A R N
C E R R 1 - L I M
C E R R 1 - W F A C
C E R R 1 - D I S A B L E
C 1 3 8 0 / 2
1
0
0
C 1 3 8 7 / 1
C 1 3 8 6 / 1
C 1 3 8 5 / 1
C 1 3 8 4 / 1
C E R R 1 - W - L I M
Fig. 3−56
Following error monitoring (CERR)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
CERR1−WFAC
a
C1385/1
dec [%]
C1384/1 1
Reduction factor for CERR1−WARN:
+100 % = no reduction
<100 % = reduction
>100 % = increase
CERR1−DISABLE
d
C1387/1
bin
C1386/1 1
HIGH sets CERR1−WARN and CERR1−EER = 0
CERR1−PHI−IN
ph
C1389/1
dec [inc]
C1388/1 4
Input
CERR1−LIM
ph
C1389/2
dec [inc]
C1388/2 4
Switching threshold, the absolute value is generated from the
input value
CERR1−ERR
bin
Input value CERR1−PHI−IN has exceeded the limit CERR1−LIM
CERR1−WARN
bin
Input value CERR1−PHI−IN has exceeded the limit
CERR1−LIM × CERR1−WFAC / 100 %
CERR1−WLIM
ph
Warning limit in inc
Function
l
Evaluation of the following error
l
Defenition of the following error limits
l
Output of status signals
l
Deactivation of the output
Summary of Contents for EVS93 Series
Page 2: ......
Page 8: ...Preface and general information 1 2 l EDSVS9332K EXT EN 4 0...
Page 14: ...Preface and general information Definition of the notes used 1 8 l EDSVS9332K EXT EN 4 0...
Page 16: ...Configuration 2 2 l EDSVS9332K EXT EN 4 0...
Page 28: ...Configuration Operating modes 2 3 2 Control 2 14 l EDSVS9332K EXT EN 4 0...
Page 32: ...Function library 3 4 l EDSVS9332K EXT EN 4 0...
Page 362: ...Application examples 4 2 l EDSVS9332K EXT EN 4 0...
Page 374: ...Application examples 4 4 Mark controlled cam profile start 4 14 l EDSVS9332K EXT EN 4 0...
Page 376: ...Appendix 5 2 l EDSVS9332K EXT EN 4 0...
Page 385: ......