Parameter reference
Parameters of the Communication Unit
96
Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 3.0 - 02/2019
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13017
C13018
C13019
Parameter | Name:
C13017 | Ethernet Config Control
Data type: UNSIGNED_16
Index: 11558 = 0x2D26
Setting of the baud rate for the Ethernet connections
Selection list
0 Auto-Negotiation
1 10 Mbps
2 100 Mbps
3 Reserved
4 Reserved
5 10 Mbps/Half Duplex
6 10 Mbps/Full Duplex
7 100 Mbps/Half Duplex
8 100 Mbps/Full Duplex
9 Reserved
10 Reserved
11 Reserved
12 Reserved
Subcodes
Lenze setting
Info
C13017/1
0: Auto-Negotiation
Ethernet setting port X31
C13017/2
0: Auto-Negotiation
Ethernet setting port X32
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13018 | Multicast Config Alloc Control
Data type: UNSIGNED_8
Index: 11557 = 0x2D25
Selection for multicast IP addressing via instance attribute 9 (Mcast Config) in the
TCP/IP Interface Object (245 /
Selection list
(Lenze setting printed in bold)
0 Default Allocation Algorithm
1 Multicast IP Start Address
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13019 | Multicast Config TTL Value
Data type: UNSIGNED_8
Index: 11556 = 0x2D24
Setting of the multicast TTL value for the validity time of data packets in the EtherNet/IP network
(Instance attribute 8 (TTL Value) in the
TCP/IP Interface Object (245 / 0xF5) (
Setting range
(min. value | unit | max. value)
Lenze setting
1
255
1
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM