Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 3.0 - 02/2019
139
Implemented CIP™ objects
Lenze objects
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
14.4
Lenze objects
14.4.1
Lenze Class (101 / 0x65)
The "Lenze Class (101 / 0x65)" enables the access to the adjustable error responses to EtherNet/IP
errors which can be set in code
.
Class attributes
Instance attributes
Note
The attributes of this class are described in the EDS file. Using the »RSNetWorx«
Rockwell software, the attributes can thus be directly set under "Parameters" in the
properties dialog of the EtherNet/IP node.
Attribute
ID
Service
Name
Data type
Value
1
Get
Revision
UINT
2 (0x0002)
2
Get
Max. Instance
UINT
1 (0x0001)
Attribute
ID
Service
Name
Data type
Value
1
Get
No. of supported Attributes
USINT
6 (0x0006)
2
Get
Attribute List
USINT
1 (0x0001) ... 6 (0x0006)
3
Get / Set Reaction on Idle Mode
USINT
Corresponds to the value in
:
• 0 = no response
• 1 = error
• 4 = warning locked
4
Get / Set Reaction on Fault Mode
USINT
Corresponds to the value in
:
• 0 = no response
• 1 = error
• 4 = warning locked
5
Get / Set Reaction on Expl. Msg. TO
USINT
Corresponds to the value in
:
• 0 = no response
• 1 = error
• 4 = warning locked
6
Get / Set Reaction on I/O Timeout
USINT
:
• 0 = no response
• 1 = error
• 4 = warning locked