Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 3.0 - 02/2019
137
Implemented CIP™ objects
"AC Drive Profile" objects
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
14.3.3
AC Drive Object (42 / 0x2A)
The "AC Drive Object" describes the device-specific functions of the inverter, e.g. speed ramps,
torque control etc.
Class attributes
Instance attributes
Attribute
ID
Service
Name
Data type
Value
1
Get
Revision
UINT
1 (0x0001)
2
Get
Max. Instance
UINT
1 (0x0001)
3
Get
Number of Instances
UINT
1 (0x0001)
Attribute
ID
Service
Name
Data type
Value
1
Get
NumAttr
USINT
Number of supported attributes
2
Get
Attributes
ARRAY of
USINT
Listing of the supported attributes
3
Get
AtReference
BOOL
1: The inverter currently runs at reference
speed or reference torque (depending on
attribute 6, DriveMode).
4
Get / Set NetRef
BOOL
• 0: Reference via local setting on the device
or terminal
• 1: Reference via network (e.g. from the
scanner)
6
Get / Set DriveMode
USINT
Drive mode:
• 1: Idle speed (frequency)
• 3: Torque control
In order to be able to use the torque control
for the
assembly object instances 22 (0x16),
23 (0x17), 72 (0x48), 73 (0x49)
, this attribute
has to be written.
7
Get
SpeedActual
INT
Current speed
[rpm/2
SpeedScale
]
8
Get / Set SpeedRef
INT
Reference speed
[rpm/2
SpeedScale
]
11
Get
TorqueActual
INT
Current torque
[Nm/2
TorqueScale
]
12
Get / Set TorqueRef
INT
Reference torque
[Nm/2
TorqueScale
]
22
Get / Set SpeedScale
SINT
Speed scaling factor
[Nm/2
SpeedScale
]
Value range: -128 ... 127
24
Get / Set TorqueScale
SINT
Torque scaling factor
[Nm/2
TorqueScale
]
Value range: -128 ... 127
29
Get / Set RefFromNet
BOOL
Status of reference speed / reference torque
• 0: Reference via local setting on the device
or terminal
• 1: Reference via network (e.g. from the
scanner)