This chapter supplements the parameter list and the table of attributes for the Inverter Drive 8400
contained in the software manual and in the »Engineer« online help by the parameters of the
communication module E84AYCEO (EtherNet/IP).
13.1
Parameters of the communication module
This chapter lists the parameters of the E84AYCEO communication module (EtherNet/IP) in
numerically ascending order.
C13000
C13001
Software manual/»Engineer« online help for Inverter Drives 8400
Here you will find general information on parameters.
Parameter | Name:
C13000 | IP Address
Data type: UNSIGNED_8
Index: 11575 = 0x2D37
Setting of the IP address
Setting the IP configuration of the Inverter Drive 8400 (
Setting range
(min. value | unit | max. value)
0
255
Subcodes
Lenze setting
Info
C13000/1
192
IP address (most significant byte)
C13000/2
168
IP address
C13000/3
124
IP address
C13000/4
16
IP address (least significant byte)
Read access
Write access
CINH
PLC STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13001 | Subnetwork Mask
Data type: UNSIGNED_8
Index: 11574 = 0x2D36
Setting of the subnet mask
Setting the IP configuration of the Inverter Drive 8400 (
Setting range
(min. value | unit | max. value)
0
255
Subcodes
Lenze setting
Info
C13001/1
255
Subnet mask (most significant byte)
C13001/2
255
Subnet mask
C13001/3
255
Subnet mask
C13001/4
0
Subnet mask (least significant byte)
Read access
Write access
CINH
PLC STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT