ERB

l

ERBGxxxxxxxx

Brake resistor

Mounting Instructions

L−force

  Drives

Summary of Contents for ERBG Series

Page 1: ...EDKRBG018R RI RI ERB l ERBGxxxxxxxx Brake resistor Mounting Instructions L force Drives...

Page 2: ...Please read these instructions and the documentation of the standard device before you start working Observe the safety instructions given therein...

Page 3: ...3 Product description 38 3 1 Overview 38 3 2 Identification 39 3 3 Application as directed 40 3 4 Dimensioning conditions 41 4 Technical data 43 4 1 General data and operating conditions 43 4 2 Rated...

Page 4: ...directed at qualified skilled personnel according to IEC 60364 Qualified skilled personnel are persons who have the required qualifications to carry out all activities involved in installing mounting...

Page 5: ...es Spelling of numbers Decimal separator Point In general the decimal point is used For instance 1234 56 Warnings UL warnings J Are only given in English UR warnings O Text Program name PC software Fo...

Page 6: ...ough dangerous electrical voltage Reference to an imminent danger that may result in death or serious personal injury if the corresponding measures are not taken Danger Danger of personal injury throu...

Page 7: ...ication note for the operation of a UL approved device in UL approved systems Possibly the drive system is not operated in compliance with UL if the corresponding measures are not taken O Warnings Saf...

Page 8: ...cations of the corresponding enclosed documentation must be observed This is vital for a safe and trouble free operation and for achieving the specified product features The procedural notes and circu...

Page 9: ...ly Select the mounting location so that the operating conditions mentioned in the technical data are always ensured Danger Hot surface during operation During operation the brake resistor becomes very...

Page 10: ...t Possible consequences The brake resistor is destroyed The drive is not braked but coasts to a standstill Protective measures Always connect the thermal contact of the brake resistor Integrate the th...

Page 11: ...ion Temperature tests have been conducted for continuous duty as indicated in the rating table with closed bottom surface The heat capability and the maximum temperature rise for higher current rating...

Page 12: ...R ES IT 7 0 3 Product description 3 1 Overview ERBG001 Scope of supply Pos Description Brake resistor Mounting Instructions Brake resistor elements Pos Description 0 Nameplate 1 Cable gland for brake...

Page 13: ...Identification 3 l 39 EDKRBG018R DE EN FR ES IT 7 0 3 2 Identification Lenze Type ERBG002 Type code ERBx xxxx xxxx Product series Resistance RB W e g 470R 470 W 075D 7 5 W Permanent power Pd W e g 120...

Page 14: ...ich the brake resistor is to be mounted complies with the regulations of the EC Machinery Directive are electrical equipment for mounting in control cabinets or similar closed electrical operating are...

Page 15: ...ntact and integrate it in a way into the system monitoring that the mains supply will be switched off when the standard device is overheated At all times the following must apply In the time interval...

Page 16: ...cyc RB 150 s t t brk brk max 7 s S t t brk brk max 6 5 s S S t t brk brk max 6 5 s 10 10 50 50 100 100 200 200 150 150 t brk s t s 1 1 1 1 1 t cyc Prs 1 1 t cyc Prs 1 1 t cyc Prs 1 1 t cyc Prs 1 1 1 t...

Page 17: ...equipment Enclosure EN 60529 IP20 NEMA 250 Protection against contact to type 1 Thermal contact Design NC contact 100 C Switching capacity 250 V AC 2 5 A 110 V AC 1 6 A Environmental conditions Clima...

Page 18: ...the chapter General data l Flammable materials or substances may not be placed in the vicinity of the brake resistor l The heat generated by the brake resistor must be dissipated freely Mounting posi...

Page 19: ...1500 ERBG018R04K3 18 0 4300 645 RB Resistance Pd Permanent power QB Heat quantity Umax Max operating voltage Temperatures Tnom TTK Tmax C Inside 390 530 690 At the housing 200 240 300 On the clearance...

Page 20: ...d e g1 mm kg ERBG023D05K6 486 302 380 400 426 6 3 15 9 ERBG028D04K1 12 8 ERBG035D03K3 300 326 12 6 ERBG043D03K0 11 8 ERBG005R02K6 11 0 ERBG075D01K9 210 236 9 5 ERBG012R01K9 ERBG012R05K2 400 426 15 1 E...

Page 21: ...ical data Mechanical data 4 l 47 EDKRBG018R DE EN FR ES IT 7 0 Free spaces for standard mounting ERBG005 All dimensions in millimetres Free spaces for mounting variant ERBG006 All dimensions in millim...

Page 22: ...e mounting location The mounting location must always ensure the operating conditions mentioned in the technical data if required additional measures must be taken Ensure unimpeded air circulation for...

Page 23: ...ring apparatus in such a way that the supply of power to the standard device is switched off if the brake resistor overheats e g switch off by means of mains contactor control 6 2 Connection data Conn...

Page 24: ...EDKRBG018R DE EN FR ES IT 7 0 6 3 Connection plan Version 1 short cables RB RB1 RB2 0 5 m PE T1 T2 ERBG008 Twisted cables Version 2 long cables RB RB1 RB2 5 m PE PES PES T1 T2 ERBG007 HF shield termin...

Page 25: ...onnections RB1 RB2 and PE of the brake resistor observing the tightening torque PE connection to EN 61800 5 1 Tighten the cable gland 0 For shielded cables Securely connect the shield to the cable gla...

Page 26: ...52 EDKRBG018R DE EN FR ES IT 7 0 5 Mount the terminal cover Note If the brake resistor is switched on for the first time or has not been used for a longer period of time a smell may develop together...

Page 27: ...till corresponds to the operating conditions included in the technical data no dust or dirt impedes the heat dissipation of the brake resistor the mechanical and electrical connections are correct 7 2...