
Electrical installation
Synchronisation of the standard device
EDK2192IB DE / EN / FR 2.0
42
l
H2_Synchronisation_Grundgeraet−2192ECAT_Synchronisation_Grundgeraet
Synchronisation of the standard device
The synchronisation of the standard device via the EtherCAT fieldbus ˘ if it is supported ˘
can be carried out via the 3−pin plug connector with screw connection (sync).
)
Note!
ECS servo system
ƒ
For the ECS axis modules, a synchronisation with operating system
software version
8.3 is possible.
ƒ
For the ECS power supply module a synchronisation is not supported.
Wire ...
ƒ terminal "0" to the corresponding sync input of the standard device (see
documentation of the standard device).
ƒ the sync supply to the 24V supply of the communication module or the standard
device.
O
p
t
o
0
E
th
er
C
A
T-
S
y
nc
W
2192ECAT002
Terminal
Description
+
External sync supply (SELV/PELV)
U = 24VDC(20.4 V − 0%... 28.8 V +0%)
0
Sync output
(t = 150
s, I
max
= 10 mA at 24 V)
−
Reference potential for external sync supply