Commissioning
Configuring power supply enable input
65
EDBCSXE040 EN 6.0
STOP key of the keypad XT
The STOP key only functions if controlled via digital inputs (C0001 = 1).
ƒ
The function of the STOP key can be set in the GDC parameter menu (
71) under
Keypad configuration
via C0469.
Stop!
Do not change the function of the STOP key if the STOP function has
previously been activated by pressing the STOP key. The device cannot be
restarted in this case.
Parameter
C0469
Designation
Function of "STOP" keypad key for ECSxE
Data type: INTEGER_32
Index: 24106
dec
= 5E2A
hex
Setting of the "STOP" keypad key function of the ECSxE power supply module
Note:
The parameters can only be changed if the controller is inhibited.
Selection list
(Lenze setting printed in bold)
Information
0 No function
1 Mains disconnection (slow
discharge)
2 Quick discharge (short−circuit
braking)