Function library
AIF1In
250
EDBCSXS064 EN 4.0
User data
Each of the eight bytes of received user data is assigned to different signal types. For this
reason, they can be evaluated —as required— as
ƒ
digital signals (1 bit)
ƒ
control word / analog signals (16 bits)
ƒ
phase signals (32 Bit)
in the axis module:
Byte
Digital signals (1 bit)
Analog signals (16 bit)
Phase signals (32 Bit)
1, 2
AIF1In−Ctrl.Bit0
AIF1In−Ctrl.Bit1
AIF1In−Ctrl.Bit2
AIF1In−Ctrl.Quickstop_B3
AIF1In−Ctrl.Bit4
...
AIF1In−Ctrl.Bit7
AIF1In−Ctrl.Disable_B8
AIF1In−Ctrl.CInhibit_B9
AIF1In−Ctrl.TripSet_B10
AIF1In−Ctrl.TripReset_B11
AIF1In−Ctrl.Bit12
...
AIF1In−Ctrl.Bit15
AIF1In−DctrlCtrl
AIF1In−W0/W1
Note:
The internal control word is firmly allocated to bytes 1 and 2. Via this
control word it is possible touse
l
signals for the functions "quick stop" (QSP), DISABLE, CINH,
TRIP−SET und TRIP−RESET and
l
the other 11 control bits (AIF1In−Ctrl.Bit...)
in further functions/function blocks.
3, 4
AIF1In−W1.Bit0
...
AIF1In−W1.Bit15
AIF1In−W1
5, 6
AIF1In−Bit0
...
AIF1In−Bit15
AIF1In−W2
AIF1In−W2/W3
7, 8
AIF1In−Bit16
...
AIF1In−Bit31
AIF1In−W3