Parameter reference
13.3
Parameters of the communication module for slot MXI2
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C14874
C14875
C14880
Parameter | Name:
C14874 | CIP Connections Timeout Time
Data type: UNSIGNED_32
Index: 9701 = 0x25E5
Display of the timeouts (ms) of the CIP connections
Display range
(min. value | unit | max. value)
0
ms
4294967295
Subcodes
Info
C14874/1
Timeout time of CIP connection 1
...
...
C14874/8
Timeout time of CIP connection 8
Read access
Write access
CINH
PLC STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C14875 | CIP Connections RUN/IDLE Flag
Data type: UNSIGNED_16
Index: 9700 = 0x25E4
Display of the run and idle flags of the CIP connections
Selection list
(read only)
0 Nonexistent
1 IDLE
2 RUN
Subcodes
Info
C14875/1
RUN/IDLE flag - CIP connection 1
...
...
C14875/8
RUN/IDLE flag - CIP connection 8
Read access
Write access
CINH
PLC STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C14880 | Reaction on communication fault
Data type: UNSIGNED_8
Index: 9695 = 0x25DF
Setting of the monitoring response in the event of a
Fault with regard to EtherNet/IP communication (
(Mapping of the Lenze object
A change in the monitoring response becomes immediately effective.
Selection list
0 No response
1 Fault
3 Quick stop by trouble
4 Warning Locked
6 Information
Subcodes
Lenze setting
Info
C13880/1
0: No Response
Idle Mode
C13880/2
0: No Response
Fault Mode
(only for "exclusive owner" connections)
C13880/3
0: No Response
Expl. message timeout
C13880/4
0: No Response
Overall Ethernet communication timeout
Read access
Write access
CINH
PLC STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT