E94AYCCA communication manual (CANopen®)
Implemented CANopen objects
170
L
EDS94AYCCA EN 5.0 - 06/2012
I-1401 - RPDO2 communication parameter
Communication parameter for the reception of process data via RPDO2
For assignment of the data telegram see object
I-1402 - RPDO3 communication parameter
Communication parameter for the reception of process data via RPDO3
For assignment of the data telegram see object
Index:
I-1401
Name:
RPDO2 communication parameter
Subindex
Default setting
Setting range (min. value | unit | max. value)
Access
Data type
0: highest subindex supported
5
- (only read access)
ro
U8
1: COB-ID used by RPDO
0x300 + node ID
0
4294967295 rw
U32
2: transmission type
254
0
255 rw
U8
3: inhibit time
-
- (for RPDOs unused)
rw
U16
4: compatibility entry
-
- (reserved, write or read access results in error
message 0x06090011)
rw
U8
5: event timer
-
- (for RPDOs unused)
rw
U16
Subindex
Meaning
Lenze code
1
Identifier RPDO2
• The basic setting is according to the "Predefined
Connection Set": Identifier = 0x300 + node ID
/
2
RPDO transmission type according to DS301, V4.02
/
Index:
I-1402
Name:
RPDO3 communication parameter
Subindex
Default setting
Setting range (min. value | unit | max. value)
Access
Data type
0: highest subindex supported
5
- (only read access)
ro
U8
1: COB-ID used by RPDO
0x400 + node ID
0
4294967295 rw
U32
2: transmission type
254
0
255 rw
U8
3: inhibit time
-
- (for RPDOs unused)
rw
U16
4: compatibility entry
-
- (reserved, write or read access results in error
message 0x06090011)
rw
U8
5: event timer
-
- (for RPDOs unused)
rw
U16
Subindex
Meaning
Lenze code
1
Identifier RPDO3
• The basic setting is according to the "Predefined
Connection Set": Identifier = 0x400 + node ID
/
2
RPDO transmission type according to DS301, V4.02
/