![Lenze E94APNE0 4 Series Mounting Instructions Download Page 47](http://html1.mh-extra.com/html/lenze/e94apne0-4-series/e94apne0-4-series_mounting-instructions_1882533047.webp)
Wiring the installation backplane
Wiring
Connecting busbars
5
47
EDK94PNE36 DE/EN/FR/ES/IT 2.0
5.3
Wiring
5.3.1
Connecting busbars
SSP94PN201
Fig.12-2
Example: connecting busbars to DC power supply module
Proceed as follows to connect the busbars:
1. If devices of the interconnected system have already been in operation:
– Ensure that the power supply system is switched off by checking the voltage at the
supply terminals.
– If necessary, switch off the power supply and wait at least 3 minutes.
2. Loosen the busbar screws but do not remove them completely.
3. Push the busbars as far as possible to the left towards the adjacent busbar.
– Ensure that there is good contact to the adjacent busbar.
4. Tighten the busbar screws.
– Tightening torque: 3.2 ... 3.5 Nm (28 ... 31 lb-in).
5. Screw all components onto the mounting plate.
– Tightening torque: 3.4 Nm (30 lb-in).