Lenze · Inverter Drive 8400 motec (PROFINET® option) · DMS 5.0 EN · 02/2019 · TD23
77
13
Parameter reference
13.2
Parameters relevant for PROFINET communication
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13002
C13003
C13010
Parameter | Name:
C13002 | Gateway address
Data type: UNSIGNED_32
Index: 11573
d
= 2D35
h
Setting of the gateway address
Setting the IP configuration (
Setting range
(min. value | unit | max. value)
Lenze setting
0
4294967295
0
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13003 | Physical address
Data type: OCTET_STRING
Index: 11572
d
= 2D34
h
Display of the MAC-ID
Subcodes
Info
C13003/1
MAC ID: Station
C13003/2
MAC ID: Port1
C13003/3
MAC ID: Port2
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13010 | Active IP address
Data type: UNSIGNED_8
Index: 11565
d
= 2D2D
h
Display of the active IP address
• The active IP address may differ from the contents of code
, depending on whether the station name was
changed via the fieldbus or the parameter.
Display range
(min. value | unit | max. value)
0
255
Subcodes
Info
C13010/1
Active IP address.1
C13010/2
Active IP address.2
C13010/3
Active IP address.3
C13010/4
Active IP address.4
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT