Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 2.0 - 10/2013
118
Implemented CIP™ objects
General CIP objects
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Data mapping of the output assemblies
Note!
In order to be able to use the torque control for the
assembly object instances 22 (0x16),
23 (0x17), 72 (0x48), 73 (0x49)
, the "DriveMode" attribute has to be written by means of
explicit message transfer.
Data component
[Bits 0 ... 7]
Class
Instance
Number
Attribute
Name
Number
Name
Number
RunFwd [Bit 0]
Control
Supervisor
0x29
1
Run1
3
RunRev [Bit 1]
Control
Supervisor
0x29
1
Run2
4
FaultReset [Bit 2]
Control
Supervisor
0x29
1
FaultRst
12
NetCtrl [Bit 5]
Control
Supervisor
0x29
1
NetCtrl
5
NetRef [Bit 6]
AC Drive
0x2A
1
NetRef
4
Drive Mode [Bits 0 ... 7]
AC Drive
0x2A
1
DriveMode
6
Speed Reference [Bits 0 ... 7]
AC Drive
0x2A
1
SpeedRef
8
Torque Reference [Bits 0 ... 7]
AC Drive
0x2A
1
TorqueRef
12
Custom Output [Bits 0 ... 7]
Note!
In case of the
assembly object instances 21 (0x15) and 23 (0x17)
,
NetCtrl (Bit 5)
and
NetRef (Bit 6)
have to be set in order that the drive can receive start/stop commands and
speed/torque commands via the network.