Electrical installation
Wiring
EDK82ZAFSC−010 DE/EN/FR 6.1
39
H2_verdrahtung_EN−INS_Klemmenbeleg
Wiring
Terminal data
Area
Values
Electrical connection
Plug connector with spring connection
Possible connections
rigid:
1.5 mm
2
(AWG 16)
flexible:
without wire end ferrule
1.5 mm
2
(AWG 16)
with wire end ferrule, without plastic sleeve
1.5 mm
2
(AWG 16)
with wire end ferrule, with plastic sleeve
0.5 mm
2
(AWG 20)
Stripping length
9 mm
Stop!
Observe the following to prevent any damage to plug connectors and
contacts:
ƒ
Only pug in / unplug the plug connectors when the controller is
disconnected from the mains.
ƒ
Wire the plug connectors before plugging them in.
ƒ
Unused plug connectors must also be plugged in.
Use of plug connectors with spring connection
E82ZAFX013