Technical data
Terminal description
Supply modules
l
48
EDS700ACBA EN 5.1
Mains connection
X100
Labelling
Description
PE
Protective earth
+
L1
Mains phases 3 PE / AC 400/480 V
L2
L3
i700P003
Terminal data
Conductor cross−section
Tightening torque
!
[mm
2
]
[AWG]
[Nm]
[lb−in]
flexible
0.5 ... 16
22 ... 6
1.2 ... 1.5
10.6 ... 13.3
5.5 x 1
X100 Electrical data
L1
L2
L3
PE
Rated voltage
400/480 V
Voltage range
320 ... 528 V
P
E
L
3
L
2
L1
+
+
3
P
E
/ A
C
X
100
P
E
L
3
L
2
L1
+
U
G
-U
G
i700S010 7
Fig. 3
Wiring of X100
X100
Mains voltage connection of power supply module
L1, L2, L3
Mains phases 3 / AC
PE
PE conductor,
+
UG (+, −)
DC bus