background image

RGB ELEKTRONIKA AGACIAK CIACIEK

SPÓŁKA JAWNA

 
Jana Dlugosza 2-6 Street

51-162 Wrocław

Poland

      [email protected]
     +48 71 325 15 05

www.rgbautomatyka.pl

www.rgbelektronika.pl

DATASHEET

www.rgbautomatyka.pl
www.rgbelektronika.pl 

 

OTHER SYMBOLS:

6409-01 07/07 CSB7_TAST

LENZE

Summary of Contents for Command Station CS 5000 DVI

Page 1: ...KA JAWNA Jana Dlugosza 2 6 Street 51 162 Wroc aw Poland biuro rgbelektronika pl 48 71 325 15 05 www rgbautomatyka pl www rgbelektronika pl DATASHEET www rgbautomatyka pl www rgbelektronika pl OTHER SY...

Page 2: ...d with a wide variety of tools and having several testing stands at their disposal are a guarantee of the highest quality service OUR SERVICES ENCODERS SERVO DRIVERS LINEAR ENCODERS SERVO AMPLIFIERS C...

Page 3: ...er F1 F2 F5 F3 F4 F11 F10 F9 F8 F12 F7 F6 Shift Alpha Bs Space Enter Esc Del Ins Menu Alt Ctrl Home 1 I 0 M 4 E 7 A Pg Dn 3 J K L N O P Pg Up End Status Power Fail 2 6 F G H 9 B C D 5 8 5 4 6 8 7 9 1...

Page 4: ...Please read these instructions before you start working Follow the enclosed safety instructions...

Page 5: ...ply 13 3 2 Application as directed 14 3 3 Device features 14 3 4 Identification 17 3 5 Controls and displays 18 3 6 Options 19 3 6 1 Add on components 19 4 Technical data 21 4 1 General data and opera...

Page 6: ...the front face option 38 6 3 7 Mounting frame connecting plate option 39 6 4 Assignment of the operator console connector board only CS 5010 DVI 40 7 Operation 41 7 1 Important notes 41 7 2 Controls a...

Page 7: ...t all activities involved in installing mounting commissioning and operating the product Tip Information and auxiliary devices related to the Lenze products can be found in the download area at http w...

Page 8: ...ers Decimal separator Point In general the decimal point is used For instance 1234 56 Warnings UL warnings Given in English and French UR warnings Text Program name PC software For example Engineer Gl...

Page 9: ...g measures are not taken Danger Danger of personal injury through a general source of danger Reference to an imminent danger that may result in death or serious personal injury if the corresponding me...

Page 10: ...operation Surfaces can be hot For Lenze drive and automation components only use approved accessories only use original manufacturer spare parts All specifications of the corresponding enclosed docum...

Page 11: ...to the PE conductor Additional notes are included in the documentation When working on live products observe the applicable national regulations for the prevention of accidents e g BGV 3 The document...

Page 12: ...gulations 2 2 Product specific safety instructions Protect the device against direct solar radiation since the housing may heat up strongly The device is classified as a class A device and can cause r...

Page 13: ...bility These devices are evaluated to meet environmental UL Type 1 Enclosure requirements when all openings in the enclosure back are closed filled by devices with suitable environmental type ratings...

Page 14: ...un coffret de type 1 toutes les ouvertures l arri re du coffret tant ferm es obtur es par des dispositifs appropri s Pour cela il convient d utiliser une traverse de support syst me bras porteur appro...

Page 15: ...ble length 2 m 1 Fixing adapter option 1 DVD PC based Automation 1 Test report 1 Device pass card Note After receipt of the delivery check immediately whether the items match the accompanying papers W...

Page 16: ...r traffic control in flight control systems for the monitoring control of nuclear reactions for the monitoring control of means of mass transport for the monitoring control of medical systems for the...

Page 17: ...Power l XGA touchscreen 38 1 cm 15 l 3 freely assignable function keys l Up to 7 freely assignable switching elements l Emergency off switch CS57x0 027 Command Station CS 5050 DVI Q R F1 F2 F5 S T F3...

Page 18: ...5 4 6 8 7 9 1 2 3 0 Alt Strg T F4 D E W Q X Y S A F3 F1 F2 R V C F F5 G H J _ F9 F8 F6 F7 F10 O I P U Z M L K N B Space Enter F12 Esc F11 Pos 1 Einfg Ende Entf Bs Alt Gr Fail Status Power Bild Bild l...

Page 19: ...CE mark Type code xxxx 2 x x x 6300 CS 5000 DVI 6301 CS 9000 DVI 6302 CS 5010 DVI 6303 CS 5050 DVI 6304 CS 5070 DVI keyboard layout German 6305 CS 5000 DVI keyboard layout English Front face USB socke...

Page 20: ...VI USB A USB B 24 V DC 0V U CS50x0 001 Pos Description Command Station here CS 5000 DVI Mounting frame Screen Status LEDs Power Fail Status Front face control elements Front face USB port option Mount...

Page 21: ...eir order specifications the operator consoles can be assembled wired and labelled with control and display elements by the factory The operator consoles can be assembled with RAFI control display ele...

Page 22: ...5 Esc F1 F2 Z T R W U Rollen Druck Entf Pos 0 F8 F9 F12 F10 F11 Einfg P O l MF2 keyboard with long throw keys in stainless steel finish l Internal cabling for Command Station with USB plug l Design ty...

Page 23: ...IP65 UL 508 NEMA 250 Type 1 enclosure pollution degree 2 Add on components EN 60529 IP65 Class of protection 3 EMC Noise emission EN 61000 6 4 Class A industrial premises Noise immunity zone B EN 610...

Page 24: ...irect fixing to a wall protected against direct solar radiation Ambient conditions Climatic Storage 10 60 C Transport 10 60 C Operation 5 45 C Relative humidity 10 90 non condensing Site altitude Stor...

Page 25: ...250 1 550 40 000 CS 5010 DVI CS 5050 DVI CS 5070 DVI CS 9000 DVI 1 4 48 3 19 5 4 1280 x 1024 300 1 2000 50 000 Operator console Control desk switching elements Type Max switching voltage Max switching...

Page 26: ...00 5 2 5 5 CS57x0 002 All dimensions in millimetres Dimensions a b e mm CS 5000 DVI 466 355 68 CS 5010 DVI 466 430 78 CS 5050 DVI 500 330 68 CS 5070 DVI 499 410 78 CS 9000 DVI 506 410 78 Add on compon...

Page 27: ...F12 F12 F10 F10 F11 F11 Einfg P O 183 184 172 466 CSB14 168 171 150 466 Strg Strg Alt Alt N H G B V S A Y X F D C K J M _ Einfg Entf Bild Bild Ende AltGr AltGr Strg Strg 6 Enter 3 5 2 4 1 0 L Q E I 6...

Page 28: ...ach time before you mount the device check whether the gasket is intact Stop Sensitive touchscreen surface The touchscreen foil is very sensitive to external forces and can be damaged by improper hand...

Page 29: ...surface cushioned with a blanket The work surface must be stable sufficiently large and free of any objects The touchscreen will be damaged when being laid on objects as for instance screws 2 Remove s...

Page 30: ...ired take additional measures Without add on component 1 0 6 1 3 2 1 CS57x0 005 How to proceed 1 Check support arm system for professional mounting and sufficient carrying capacity See support arm doc...

Page 31: ...adapter plate on the side with the threaded bolts 3 Pull the connecting cables out of the support arm and screw the adapter plate to the support arm For screws see support arm documentation 4 Screw th...

Page 32: ...3 3 CS57x0 010 How to proceed 1 Prepare the wall for mounting the wall bracket The mounting location and the installation material must provide for a permanent mechanical connection 2 Stick the self a...

Page 33: ...with the threaded bolts 3 Screw the wall bracket and the adapter plate to the swivel adapter 2 x 4 countersunk head screws M5 x 16 mm with washers 5 3 mm and nuts M5 4 Pull the connecting cable throu...

Page 34: ...e a new labelling strip according to the following outline 028 8 x 15 5 40 16 4 6 x 40 240 315 1 2 x 45 18 5 S1 S2 S3 S4 S5 S6 S7 CSB 004 Fig 5 1 Labelling strip sizes Maximum labelling field sizes Al...

Page 35: ...asures Handle the gasket with care during mounting Protect the gasket against ultraviolet rays Each time before you mount the device check whether the gasket is intact Stop Sensitive touchscreen surfa...

Page 36: ...pply when working on the device This particularly applies Before connecting disconnecting connectors Before plugging in plugging out modules All persons handling printed circuit boards have to take ac...

Page 37: ...device to the earthed mounting plate Mounting plates with an electroconductive surface zinc coated or stainless steel allow for continuous contacting Coated plates are not suitable for an EMC complia...

Page 38: ...the mounting frame it may fall down Possible consequences The screen is damaged Injuries by the falling device Protective measures Secure screen against falling down 0 2 1 3 4 max 12 kg 1 0 0 1 0V U 0...

Page 39: ...bserve the max permissible input voltage Professionally fuse the device on the input side against voltage variations and voltage peaks 6 3 3 24 V connection Description Connection type Cable type 0V U...

Page 40: ...link 18 1 DVI D double link 24 1 IPC001 6 3 5 USB interface Description Connection type Cable type USB 2 0 host connection Max load 5 V 500 mA USB A socket USB cable with USB A plug IPC001 Descriptio...

Page 41: ...e blanking plate in the mounting frame by a connecting plate which serves to connect further interfaces The following interfaces are available Description Connection type Cable type Universalkupplung...

Page 42: ...isplay elements of the control desk 10 pole Phoenix Combicon socket with spring pressure connection type FK MC 0 5 10 ST 2 5 Flexible due to wire end ferrule conductor cross section 0 14 0 5 mm2 CSB 0...

Page 43: ...d by improper handling Possible consequences The touchscreen foil becomes damaged scratched or dull Protective measures Avoid contact of the touchscreen foil with pointed or hard objects Always use a...

Page 44: ...e Service mode Switch on mode Press for 4 s Switch off mode Press or wait for 35 s Display Application dependent Status LEDs Power green l Is ON when the supply voltage is present Fail red l Is On whe...

Page 45: ...tch off mode Press or wait for 35 s Display Application dependent Status LEDs Power green l Is ON when the supply voltage is present Fail red l Is On when a power supply failure has occurred l Is blin...

Page 46: ...ssing Status yellow l Indicates access to a storage medium Function keys F1 F12 Send key code for Shift F1 Shift F12 F1 F12 Send key codes for Q Tool Application dependent Increase screen brightness R...

Page 47: ...cation dependent Status LEDs Power green l Is ON when the supply voltage is present Fail red l Is ON when a power supply failure has occurred l Is blinking when the screen signal is missing Status yel...

Page 48: ...asures Contacts of plug connectors must not be touched Printed circuit boards may be touched only at places free from electrical contacts and may be placed only on appropriate materials e g on ESD pac...

Page 49: ...Before cleaning disconnect the device from the power supply and the optionally UPS power supply as otherwise unintentional commands may be activated via the touchscreen for example a response of the c...

Page 50: ...oving and mounting the screen Stop Screen may fall down If the screen is not screwed together with the mounting frame it may fall down Possible consequences The screen is damaged Injuries by the falli...

Page 51: ...nce Repair Removing and mounting the screen 8 49 BA_CS9000DVI EN 4 0 Mounting 0 2 1 3 4 max 12 kg 1 0 0 1 0V U 0V U 0V U CS50x0 012 Mounting frame Screen Attachment PE connecting cable Other connectin...

Page 52: ...he supply voltage applied is too high Possible consequences The device can be damaged if a non approved fuse is installed Protective measures The fuse may only be replaced by an approved type Approved...

Page 53: ...8 E Electrical data 23 Electrical installation 33 EMC compliant wiring 35 Mains 37 monitor 38 Operator console CSB 7 14 40 Terminal diagram 37 UPS 40 USB front panel 38 internal 38 USB connection 38 E...

Page 54: ...10 Regular checks 46 Removing the screen 48 Repair 48 S Safety 21 Safety instructions 8 application as directed 14 definition 7 layout 7 Scope of supply 13 Screen 23 Shielding EMC 35 Short circuit 34...

Page 55: ...ze Str 1 D 31855 Aerzen Germany Service Lenze Service GmbH Breslauer Stra e 3 D 32699 Extertal Germany 49 5154 82 0 008000 2446877 24 h helpline 49 5154 82 2800 49 5154 82 1112 lenze lenze com service...

Reviews: