P94PFB01A
16
Cyclic Data Access
5.3.2 Data OUT (Dout) Channels
The PROFIBUS-DP module has 12 cyclic OUT channels each of which utilises 4 Bytes of data.
The amount of OUT channels activated and mappable is set by PID284.
OUT data mapping can be set via the MVOB [Communications] [PROFIBUS DP] folder:
Figure 14: PROFIBUS DP Communications folder
Or PIDs 286 - 297 can be used to directly edit the OUT mapping details.
PID286 to PID297 - Dout Mapping Channels
Default: Various
Range: 0 - 999
Access: RW
Type: Integer
Table 6 lists the default mapping destinations for OUT going data being sent from the network
master.
Table 6 – OUT Data (Dout) Mappings
PID
Dout Channel
Default
Format
Function
PID286
Channel 1 mapping
52
Integer
VAR_ENABLE
PID287
Channel 2 mapping
139
Float
VAR_IREF
PID288
Channel 3 mapping
102
Integer
VAR_V2
PID289
Channel 4 mapping
103
Float
VAR_V3
PID290
Channel 5 mapping
104
Integer
VAR_V4
PID291
Channel 6 mapping
105
Float
VAR_V5
PID292
Channel 7 mapping
106
Integer
VAR_V6
PID293
Channel 8 mapping
107
Float
VAR_V7
PID294
Channel 9 mapping
108
Integer
VAR_V8
PID295
Channel 10 mapping
109
Float
VAR_V9
PID296
Channel 11 mapping
110
Integer
VAR_V10
PID297
Channel 12 mapping
111
Float
VAR_V11
•
•
•
•
•