14
Parameter reference
14.2
Parameters of the communication module for slot MXI1
104
Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 10.2 EN · 11/2018 · TD06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13239
C13240
Parameter | Name:
C13239 | Mapping entries RPDO-9
Data type: UNSIGNED_64
Index: 11336 = 0x2C48
This code is for device-internal use only and must not be written to by the user!
Subcodes 1 ... 32 specify the mapping for the RPDO channel 9.
• Servo Drives 9400 exclusively support mapping objects with a data length of 8 bits (1 byte) or a multiple of this
value. Incompatible objects must be mapped to variables with a compatible data length.
• The master must have the same mapping entries as the slave.
Structure of the mapping codes (
Value is bit-coded:
Info
Bit 0 Bit 0
... ...
Bit 63 Bit 63
Subcodes
Lenze setting
Info
C13239/1
0
1. Mapping entry RPDO-9 (I-1608.01)
...
...
...
C13239/32
0
32. Mapping entry RPDO-9 (I-1608.20)
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13240 | Mapping entries RPDO-10
Data type: UNSIGNED_64
Index: 11335 = 0x2C47
This code is for device-internal use only and must not be written to by the user!
Subcodes 1 ... 32 specify the mapping for the RPDO channel 10.
• Servo Drives 9400 exclusively support mapping objects with a data length of 8 bits (1 byte) or a multiple of this
value. Incompatible objects must be mapped to variables with a compatible data length.
• The master must have the same mapping entries as the slave.
Structure of the mapping codes (
Value is bit-coded:
Info
Bit 0 Bit 0
... ...
Bit 63 Bit 63
Subcodes
Lenze setting
Info
C13240/1
0
1. Mapping entry RPDO-10 (I-1609.01)
...
0
...
C13240/32
0
32. Mapping entry RPDO-10 (I-1609.20)
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT