Parameter setting
Device information
Description of the objects
7
88
KHB 13.0003-EN 2.0
7.8
Device information
7.8.1
Description of the objects
Index
Name
Possible settings
Characteristics
Lenze
Selection
Description
6410
h
Motor_data
1 resolver_offset
1
0
{1 inc}
4096
VAR
UINT16 RW
—
Setting the resolver offset.
2 number_of_pole_
pairs
2
1
{1}
13
VAR
UINT16 RW
—
Setting the pole pair number.
Bit No.
Meaning
0 ... 3
Pole pair number
4
Reversal of direction of resolver
3 braking _times
{1 ms}
VAR
UINT32 RW
—
Setting the disengagement
and engagement time of the
brake.
Bit No.
Meaning
0 ... 15
Disengagement time
16 ... 31 Engagement time
4 brake_voltage
001A0012
{1 V}
VAR
UINT32 RW
—
Setting the value range for
the brake voltage.
Bit No.
Meaning
0 ... 15
Minimum limit value (18 ... 22 V)
16 ... 31 Maximum limit value (26 ... 32 V)
6510
h
Drive_data
0 number_of_
supported_entries
00
h
{1
h
}
03
h
VAR
UINT8
RO
—
Maximally supported
subindices.
03
h
Four subindices are
supported.
1 identification
VAR
UINT32 RO
—
Reading the identification.
2 serial_number
VAR
UINT32 RO
—
Reading the serial number.
3 operating_minutes
VAR
UINT32 RO
—
Reading the operating
minutes.