Parameter setting
Parameter setting with the XT EMZ9371BC keypad
Changing and saving parameters
17
EDKVF93−05 EN 2.0
Function keys
Note!
Shortcuts with
:
Press and hold
, then press the second key in addition.
Key
Function
Menu level
Code level
Parameter level
Operating level
Change to the
parameter level
Change to the operating
level
Change to the code
level
Go to the "Short setup"
menu and load
predefined
configurations
1)
Accept parameters
when SHPRG
or
SHPRG is displayed
Change between menu
items
Change of code number
Change of digit via
cursor
Quick change between
menu items
Quick change of code
number
Quick change of digit
via cursor
!
Change between main menu, submenu and code
level
Cursor to the right
"
Cursor to the left
#
Deactivate the function of the key
$
, the LED in the key goes off
$
Inhibit the controller, the LED in the key is lit.
Reset fault (TRIP−Reset): 1. Remove the cause of malfunction
2. Press
$
3. Press
#
1)
Only active for operation with standard devices of the 8200 vector or 8200 motec series
3.1.4
Changing and saving parameters
Note!
Your settings have an effect on the current parameters in the main memory.
You must save your settings in a parameter set so that they are not lost when
the mains are connected.
If you only need one parameter set, save your settings as parameter set 1,
since parameter set 1 is loaded automatically after mains connection.
Step
Key
sequence
Action
1.
Select the menu
! "
Use the arrow keys to select the desired menu
2.
Change to the code level
!
Display of the first code in the menu
3.
Select code or subcode
Display of the current parameter value
4.
Change to the parameter level
5.
When SHPRG is displayed, inhibit the
controller
$
1)
The drive coasts
6.
Change parameter
A
! "
Move cursor below the digit to be changed
B
Change of digit
Quick change of digit
7.
Accept the changed parameter