Troubleshooting and fault elimination
System error messages
General error messages
39
EDKVF93−05 EN 2.0
Remedy
Cause
Error
Error number
x = 0: TRIP
x = 1: Message
x = 2: Warning
Display
Pin X9/8 is not assigned
Assign pin X9/8 with 5 V or switch off
monitoring (C0587 = 3)
Sd5
x085
Encoder at X6/1,
X6/2 is defective
Current at X6/1, X6/2 < 2 mA
l
Check cable for wire breakage
l
Check encoder
Sd6
x086
Sensor error at X8
KTY at X8 indicates undefined values
l
Check supply cable for firm
connection
l
Switch off monitoring with
C0594 = 3 if necessary