Configuration
Basic configuration
2−12
l
EDSVF9383V−EXT EN 2.0
2.2.5
Traversing control (C0005 = 3000)
The configuration C0005 = 3000 is designed for spindle drives moving material by means of winding.
The speed of the winding drive is transferred via the analog input X6/1 which is used to control the
speed of the traversing drive. The reversing of the direction of rotation is controlled via the digital
inputs X5/E1 and X5/E2. Limit switches operating as normally closed contacts which disable the
active direction of rotation can for example be used for this purpose.
Short setup
The "Short setup" menu contains the following codes. In the "Short setup" menu of the XT keypad
and "Global Drive Control", the codes are listed in the following order.
Code
Explanation
Lenze setting
C0005
Selection of the basic configuration
3000
C0011
Maximum speed
Reference value for the absolute and relative setpoint selection for the
acceleration and deceleration times
3000 rpm
C0012
Acceleration time T
ir
of the main setpoint
1.00 s
C0013
Deceleration time T
if
of the main setpoint
1.00 s
C0034
Voltage / current range for analog signals at the input X6/1, X6/2
0
C0104
Selection of acceleration function of the linear ramp−function generator of NSET
2
C0141
Additional setpoint for inching, activated via input X5/E3
10.00 %
C0472/1
Selection of traversing step
100.00 %
C0474/1
Selection of traversing break
(65536 results in a break of one motor revolution, if 100 % reference setpoint = 3000 rpm)
10000 inc
C0655
Numerator
Conversion factor, function block CONV5
C0655 = 1
C0656
Denominator
C0656 = 5
C0190
Arithmetic function, function block NSET
Connects main setpoint (C0046) and additional setpoint (C0040)
0
C0105
Quick stop deceleration time
5.00 s
C0026/1
Offset of AIN1 (X6/1, X6/2)
0.00 %
C0026/2
Offset of AIN2 (X6/3, X6/4)
0.00 %
C0027/1
Gain AIN1 (X6/1, X6/2)
100.00 %
C0027/2
Gain AIN2 (X6/3, X6/4)
100.00 %
C0685
Comparison function, function block CMP2
1
C0686
Hysteresis for input signals, function block CMP2
0.00 %
C0687
Window for signal comparison, function block CMP2
0.00 %