Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
L
303
8400 motec | Software Manual
Parameter reference
Parameter list | C02607
C02607
C02610
Parameter | Name:
C02607 | Holding brake: Status
Data type: UNSIGNED_16
Index: 21968
d
= 55D0
h
Switching status of the holding brake control
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 Brake closed
Holding brake is completely applied
Bit 1 Brake released
Holding brake is completely released
Bit 2 Feedforward control active
Feedforward control for holding of the load via the motor
is active before the holding brake releases.
Bit 3 Closing active
The brake application time (
Bit 4 Forced release active
In case of automatic operation of the holding brake
control, the brake is directly released via the MCK input
bBrkRelease
= TRUE
Bit 5 Release active
The brake application time (
Bit 6 Setpoint synchronisation active
A speed setpoint at the MCK is approached along a
defined ramp after brake release
Bit 7 Brake control fault
Motor phase error detected before brake is released. For
configuration of monitoring see
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Parameter | Name:
C02610 | MCK: Accel./deceleration times
Data type: UNSIGNED_32
Index: 21965
d
= 55CD
h
From version 02.00.00
Ramp times for speed setpoint synchronisation
Setting range
(min. value | unit | max. value)
0.0
s
999.9
Subcodes
Lenze setting
Info
C02610/1
2.0 s
MCK: Holding brake ramp time synchr.
• Ramp time for approaching the speed setpoint
pending at the MCK after the holding brake release
has been completed.
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1000