Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
L
175
8400 motec | Software Manual
Basic functions
Parameter change-over
Importing/exporting the list
For cross-device reuse of the configured
WriteParamList
, you can click on the
Export list
and
Import list
buttons to save the parameter selection as an *.epc file and then to re-import
the saved *.epc file into another drive controller 8400.
8.1.2
Configuring the list by means of parameterisation
The following application example shows the necessary procedure for configuring the list
without using the »Engineer« parameterisation dialog.
Task:
The parameters
,
and
to
Compiling the parameter list
, specify the above-named parameters in the <Code>,<Subcode> format:
= 12.000
= 26.001
= 27.001
= 222.000
= 223.000
= 224.000
= 0.000 (no parameter)
Entering values for the parameters (value set 1)
In
, specify the values to be used to describe the selected parameters. The
values are entered in accordance with the scaling format / scaling factor of the respective
parameter.
= <value> for list entry 1 (in our example: for parameter
)
= <value> for list entry 2 (in our example: for parameter
= <value> for list entry 3 (in our example: for parameter
etc.
These values are used for writing if the
bSelectWriteValue_1
input is not assigned or set to
FALSE.
Note!
Gaps in the parameter list (setting = 0.000) are permissible and are skipped
during the process.
Invalid parameter entries are not accepted when being entered.
Summary of Contents for 8400 motec Series
Page 375: ...L 375 ...