8400 motec | Software Manual
Drive application
Parameterisation dialog
152
L
Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
7.1.1.1
Selection of the main speed setpoint
The main speed setpoint is selected in the Lenze setting via the analog input 1.
Scaling: 10 V
≡
100 % reference speed (
)
The main setpoint is transformed to a speed setpoint in the setpoint encoder via a ramp
function generator with linear or S-shaped ramps.
For a detailed functional description see FB
.
Related topics:
7.1.1.2
Motor potentiometer function
Alternatively, the main speed setpoint can be generated via a motor potentiometer
function.
In the Lenze setting, the motor potentiometer function is deactivated.
Activation is possible via
or via the
bMPotEnable
input.
The behaviour of the motor potentiometer during switch-on of the drive system can be
selected in
.
For a detailed functional description see FB
.
7.1.1.3
Process controller
A process controller (PID controller) is connected downstream of the setpoint generator.
In the Lenze setting, the process controller is deactivated.
The activation is executed by selecting the operating mode in
For a detailed functional description see FB
nInflu_a
(
Limitation of the influencing factor in percent
Speed setpoint
(
)
Speed setpoint
Parameter
Info