Parameter setting
6-35
L
BA2141 EN 1.0
6.5.2.2
Control word for 82XX
Bit
820X
821x,822x
Bit
820X
821x,822x
00,
00 = C0046 active
01 = JOG1 active in C0037
00 = C0046 active
01 = JOG1 active in C0037
00,
01
10 = JOG2 active in C0038
11 = JOG3 active in C0039
01 JOG1 active in C0037
10 = JOG2 active in C0038
11 = JOG3 active in C0039
02
CW/CCW (CW rotation/CCW rotation)
0 = CW rotation
1 = CCW rotation
CW/CCW (CW rotation/CCW rotation)
0 = CW rotation
1 = CCW rotation
03
QSP (quick stop)
0 = QSP not active
1 = QSP active
QSP (quick stop)
0 = QSP not active
1 = QSP active
04
Reserved
RFG stop (stop of the ramp function generator)
0 = RFG stop not active
1 = RFG stop active
05
Reserved
RFG zero (deceleration along the T
if
ramp C0013)
0 = RFG zero not active
1 = RFG zero active
06
Reserved
UP function for motor potentiometer
0 = UP not active
1 = UP active
07
Reserved
DOWN function for motor potentiometer
0 = DOWN not active
1 = DOWN active
08
Reserved
Reserved
09
Ctrl. inhibit (controller inhibit)
0 = controller not inhibited
1 = controller inhibited
Ctrl. inhibit (controller inhibit)
0 = controller not inhibited
1 = controller inhibited
10
Reserved
Reserved
11
Reserved
TRIP reset
0 -> 1 = Edge from 0 to 1
12
PAR1 (Parameter set changeover)
0 -> 1 = Parameter set
1 -> 0 = Parameter set
PAR1 (Parameter set changeover)
0 -> 1 = Parameter set
1 -> 0 = Parameter set
13
Reserved
Reserved
14
DC brake (DC injection brake)
0 = DC brake not active
1 = DC brake active
DC brake (DC injection brake)
0 = DC brake not active
1 = DC brake active
15
Reserved
Reserved
2141LON010
AIF
C0046
.B15
.B13
.B14
.B12
.B0
.B1
.B2
.B3
.B4...
...
...
.B8
.B9
.B10
.B11
QSP
CINH
TRIP-SET
TRIP-RESET
16 Bit
16 Bit
0
JOG/
C046
0 1 1
0 1 0 1
PAR
GSB
R/L
Fig. 6-6
Access to control word and actual frequency in 82XX (fixed assignment)
Show/Hide Bookmarks
Summary of Contents for 2141
Page 6: ...Contents iv L BA2141 EN 1 0 Show Hide Bookmarks ...
Page 14: ...Technical data 3 4 L BA2141 EN 1 0 Show Hide Bookmarks ...
Page 20: ...Installation 4 6 L BA2141 EN 1 0 Show Hide Bookmarks ...
Page 74: ...Parameter setting 6 52 L BA2141 EN 1 0 Show Hide Bookmarks ...
Page 76: ...Troubleshooting and fault elimination 7 2 L _ ONQN bk NKM Show Hide Bookmarks ...
Page 90: ...Appendix 8 14 L _ ONQN bk NKM Show Hide Bookmarks ...