Parameter setting
6-27
L
BA2141 EN 1.0
6.4.2.11
Receive heartbeat for AIF-CTRL
network input config SNVT_state nciAIFRecHrtBt;
Here you can select the manufacturer-specific network variables (
nviAIFStw
,
nviAIFIn1
,
nviAIFIn2
,
nviAIFIn3
) which are to be monitored with a
Receive Timeout
.
nciAIFRecHrtBt.bit0
= 0 – No timeout monitoring for
nviAIFStw
nciAIFRecHrtBt.bit0
= 1 – Timeout monitoring for
nviAIFStw
nciAIFRecHrtBt.bit1
= 0 – No timeout monitoring for
nviAIFIn1
nciAIFRecHrtBt.bit1
= 1 – Timeout monitoring for
nviAIFIn1
nciAIFRecHrtBt.bit2
= 0 – No timeout monitoring for
nviAIFIn2
nciAIFRecHrtBt.bit2
= 1 – Timeout monitoring for
nviAIFIn2
nciAIFRecHrtBt.bit3
= 0 – No timeout monitoring for
nviAIFIn3
nciAIFRecHrtBt.bit3
= 1 – Timeout monitoring for
nviAIFIn3
If one of the monitored variables gets a
Receive Heartbeat Timeout
, the function selected in
nciAIFDefStw
will be carried out.
Input range
The possible range for the input variable is 0 or 1 for every bit.
Only bits 0 and 3 will be evaluated.
Standard value
0